Monitoring

6-10

9820-A2-GB20-20

June 2000

Power Module LEDs (Model 9820-45M)

Each power module has a green LED which remains lit while power is applied
and the power module is functioning.

When the yellow front panel System PWR LED is lit, one of the power modules
has failed. The failed power module can be identified from the back of the DSU
by its unlit LED.

Table 6-8.

Power Module Troubleshooting

Configuration

Symptom

What to Do
(in order, if problem persists)

One Power
Module

No front panel LEDs are
lit.

1. Verify that the receptacle in use

provides 120 Vac.

2. Verify that the power module switch is

in the On position.

3. Replace the power module. See

Replacing a Power Module

in

Chapter 12,

Hardware Maintenance.

4. Call your service representative.

Two Power
Modules

No front panel LEDs are
lit.

1. Verify that the receptacles in use

provide 120 Vac.

2. Verify that the power module switches

are in the On position.

3. Replace the power modules. See

Replacing a Power Module

in

Chapter 12,

Hardware Maintenance.

4. Call your service representative.

The front panel System
PWR LED is lit.

1. Check the power module LEDs from the

back of the unit and replace the failed
power module (the one whose LED is
off). See

Replacing a Power Module

in

Chapter 12,

Hardware Maintenance.

2. Call your service representative.