Paradyne 9820-2M User Manual

Page 238

Advertising
background image

SNMP MIBs and Traps, and RMON Alarm Defaults

B-22

9820-A2-GB20-20

June 2000

Table B-13.

Static DLCI Alarm Defaults (2 of 2)

Item

Falling
Threshold
Default

Rising
Threshold
Default

Event
Type

Interval

MIB/Tag/OID

2

Sample
Type

1

Tx CIR Utilization

D

MIB: FR DTE MIB
(RFC 2115)

Tag: frCircuitSentOctets

OID: .1.3.6.1.2.1.10.32.2.1.
7.I.D

60 secs
(1 min)

None

Must be
configured.

0

1

D = Delta. Indicates that the calculated difference between the current value and the previous value is contained
in the MIB.
A = Absolute. Indicates that the exact value for the item is contained in the MIB.

2

I in the OID = Interface ID of the frame relay link.
D = DLCI number.

Table B-14.

Dynamic DLCI Alarm Defaults

Item

Sample
Type

1

MIB/Tag/OID

2

Interval

Event
Type

Rising
Threshold
Default

Falling
Threshold
Default

Rx DLCI Link
Utilization

D

MIB: FR DTE MIB
(RFC 2115)

Tag: frCircuitReceivedOctets

OID: .1.3.6.1.2.1.10.32.2.1.
9.I.D

60 secs.
(1 min)

Rising

70% of link
capability

65% of link
capability

Tx DLCI Link
Utilization

D

MIB: FR DTE MIB
(RFC 2115)

Tag: frCircuitSentOctets

OID: .1.3.6.1.2.1.10.32.2.1.
7.I.D

60 secs.
(1 min)

Rising

70% of link
capability

65% of link
capability

1

D = Delta. Indicates that the calculated difference between the current value and the previous value is contained
in the MIB.
A = Absolute. Indicates that the exact value for the item is contained in the MIB.

2

I in the OID = Interface ID of the frame relay link.
D = DLCI number.