Paradyne 9820-2M User Manual

Page 61

Advertising
background image

Configuration Options

4-25

9820-A2-GB20-20

June 2000

Table 4-7.

Interface Frame Relay Options (3 of 3)

LMI Heartbeat (T1)

Possible Settings: 5, 10, 15, 20, 25, 30
Default Setting: 10

Configures the LMI-defined T1 parameter, which sets the number of seconds between
the initiation of status enquiry messages on the user side of the LMI. Applies to the user
side of a UNI only.

5 – 30 – Specifies the number of seconds between the initiation of status enquiry
messages in increments of 5.

LMI Inbound Heartbeat (T2)

Possible Settings: 5, 10, 15, 20, 25, 30
Default Setting: 15

Configures the LMI-defined T2 parameter, which sets the number of seconds between
the receipt of status enquiry messages on the network side of the LMI. Applies to the
network side of a UNI only.

5 – 30 – Specifies the number of seconds between the receipt of status enquiry
messages in increments of 5.

LMI N4 Measurement Period (T3)

Possible Settings: 5, 10, 15, 20, 25, 30
Default Setting: 20

Configures the LMI-defined T3 parameter, which is the time interval (in seconds) that the
network side of the LMI uses to measure the maximum number of status enquiry
messages that have been received (N4) from the user side.

5 – 30 – Specifies the interval of time in increments of 5.

Advertising
This manual is related to the following products: