Security and Logins

5-11

9820-A2-GB20-20

June 2000

See

Configuring SNMP NMS Security Options

in Chapter 4,

Configuration

Options, for more information about SNMP NMS Security configuration options.

Creating a Login

A login is required if security is enabled. (Security is enabled by the configuration
options Login Required for the communication port, and Telnet Login Required or
FTP Login Required for a Telnet or FTP Session.)

Up to six login ID/password combinations can be created using ASCII text, and
each login must have a specified access level. Logins must be unique and they
are case-sensitive.

"

Procedure

To create a login record:

1. Select Administer Logins.

Main Menu

Control

Administer Logins

2. Select New, and set the following configuration options, as appropriate.

In the field . . .

Enter the . . .

Login ID

ID of 1 to 10 characters.

Password

Password from 1 to 10 characters.

Re-enter password

Password again to verify that you entered the
correct password into the device.

Access Level

Access level: 1, 2, or 3.

H

Level-1 – User can add, change, and
display configuration options, save, and
perform device testing.

H

Level-2 – User can monitor and perform
diagnostics, display status and
configuration option information.

H

Level-3 – User can only monitor and
display status and configuration screens.

CAUTION: Make sure at least one login is set
up for Level-1 access or you may be
inadvertently locked out.

NOTE:

See

Resetting the Unit and Restoring Communication

in Chapter 8,

Troubleshooting, should you be locked out inadvertently.