Adding slv alarms manually, Configure alarms manually, see – Paradyne 9820-2M User Manual

Page 189

Advertising
background image

Setting Up NetScout Manager Plus for FrameSaver Devices

10-11

9820-A2-GB20-20

June 2000

Adding SLV Alarms Manually

Once DLCIs have been discovered, SLV alarms should be defined and assigned
to each DLCI.

When configuring alarms manually, every alarm must be configured for each
DLCI; that is, if there are eight alarms and 20 DLCIs, 160 trap configurations
must be created (8 x 20). For this reason, it is recommended that the OpenLane
defaults be used. Follow the procedure below to configure alarms manually.

To load OpenLane default settings for alarms, see

Adding SLV Alarms Using a

Template

.

"

Procedure

1. From the NetScout Manager Plus main window, with the FrameRelay and

Admin radio buttons still selected, click on the Config Manager icon to open
the Configuration Manager main window.

2. Select the Custom radio button from the Properties File area (in the upper

right of the window), then Property... (down the center of the screen).

The Custom Property Editor window opens (see the window in

Editing

Alarms

).

3. Select a DLCI from the Trap list, and select the Add... button (to the right of

the list). The Add Trap window opens.

Advertising
This manual is related to the following products: