Setting Up NetScout Manager Plus for FrameSaver Devices

10-15

9820-A2-GB20-20

June 2000

Installing the User-Defined History Files

Once the user-defined history files have been created, the files need to be
installed. History files are installed from the command-line prompt in NetScout
Manager Plus. Should the FrameSaver unit be reset, these files will need to be
reinstalled. The command used to install a new user history table is located in
$NSHOME/bin.

CAUTION:

Do not use user_history_table_1 or 2. UserHistory1 and UserHistory2
are the default user history files used to keep SLV data for reports.
Editing either of these files will destroy SLV reporting capability.

"

Procedure

1. Type dvuhist -f

agentname user_ history_ table_ number config

number_of_buckets interval download_ file.udh to load user-defined history

files for the frame relay link.

Example:

dvuhist -f Dallas51 3 config 30 60 Dallas51k.udh

The interval must be entered in seconds.

2. Type dvuhist -f

agentname DLCI_ numberuser_ history_ table_ number

config

number_of_buckets interval download_ file.udh

to load user-defined

history files for a specific DLCI.

Example:

dvuhist -f “Dallas51 301” 3 config 30 60 Dallas301.udh

The same user history table number can be used for both the link and DLCI.
For these examples, user history table number 3 will appear as UserHistory3
on the History List.

See

Step 5

in

Monitoring a DLCI’s History Data to verify that the user-defined

history files have been loaded.

Refer to

Installing .UDH Files in Using Custom History of the NetScout Manager

Plus User Guide for additional information.