SNMP MIBs and Traps, and RMON Alarm Defaults

B-7

9820-A2-GB20-20

June 2000

Trap: warmStart

This trap indicates that the FrameSaver unit has been reset and has stabilized.

Table B-3.

warmStart Trap

Trap

What It Indicates

Possible Cause

warmStart

FrameSaver unit has just
reinitialized and stabilized
itself.

H

Reset command sent.

H

Power disruption.

String:

Variable-Binding

String:
‘Unit reset.’

devLastTrapString
(devHealthAndStatus. mib)

Trap: authenticationFailure

This trap indicates that access to the FrameSaver unit was unsuccessful due to
lack of authentication.

Table B-4.

authenticationFailure Trap

Trap

What It Indicates

Possible Cause

authenticationFailure

Access to the FrameSaver
unit was attempted and
failed.

H

SNMP protocol message not
properly authenticated.

H

Three unsuccessful attempts
were made to enter a correct
login user ID/password
combination.

H

IP Address security is enabled
and a message was received
from the SNMP Manager
whose address was not on the
lost of approved managers.

String:
‘Unauthorized access attempted.’

Variable-Binding

devLastTrapString
(devHealthAndStatus. mib)

Advertising