Signal level

RS-232C compliant

Synchronization method

Asynchronous

Baud rate

9600 bps

Parity

None

Character length

8 bits

Stop bit

1 bit

Flow control

-

RS-232C Conversion cable

D-sub 9-pin female

Details

2

R X D

3

T X D

5

GND

4

6

Non use

7
8

Shorted

1

9

NC

Command

Parameter

Control details

PON

None

Power ON

POF

None

Power OFF

AVL

**

Volume 00 - 63

AMT

0

Audio MUTE OFF

1

Audio MUTE ON

IMS

None

SL1

SL2

SL3

PC1

SL1A

SL1B

SL2A

SL2B

Input select (toggle)

Slot1 input

Slot2 input

Slot3 input∗

PC input

Slot1 input (INPUT1A)

Slot1 input (INPUT1B)

Slot2 input (INPUT2A)

Slot2 input (INPUT2B)

DAM

None

NORM

ZOOM

FULL

JUST

SELF

Screen mode select (toggle)

NORMAL (4 : 3)

ZOOM

FULL

JUST

Panasonic AUTO

SERIAL

(Example: TH-42PH10UK)

6

7

8

9

1

3

4

5

2

TH-42PH10UK, TH-50PH10UK,

TH-58PH10UK

9

8

7

6

5

3

2

1

4

TH-37PH10UK

Connections

SERIAL Terminals connection

Notes:
• Use the RS-232C cable to connect the computer to the Plasma Display.
• The computer shown is for example purposes only.
• Additional equipment and cables shown are not supplied with this set.

The SERIAL terminal conforms to the RS-232C interface specifi cation, so that the Plasma Display can be controlled by a
computer which is connected to this terminal.
The computer will require software which allows the sending and receiving of control data which satisfi es the conditions
given below. Use a computer application such as programming language software. Refer to the documentation for the
computer application for details.

The SERIAL terminal is used when the Plasma Display is controlled by a computer.

Communication parameters

Basic format for control data
The transmission of control data from the computer
starts with a STX signal, followed by the command,
the parameters, and lastly an ETX signal in that order.
If there are no parameters, then the parameter signal
does not need to be sent.

Notes:
• If multiple commands are transmitted, be sure to wait

for the response for the fi rst command to come from
this unit before sending the next command.

• If an incorrect command is sent by mistake, this unit will

send an “ER401” command back to the computer.

• SL1A, SL1B, SL2A and SL2B of Command IMS are

available only when a dual input terminal board is
attached.

• With the power off, this display responds to PON

command only.

SLOT3 cannot be selected on TH-37PH10UK.

Pin layout for SERIAL Terminal

COMPUTER

RS-232C Straight cable

D-sub 9p

Start
(02h)

3-character
command (3 bytes)

Colon

Parameter(s)
(1 - 5 bytes)

End
(03h)

STX

C1 C2 C3

P1 P2 P3 P4

:

P5

ETX

Command

Advertising