Warning system, Warning description tables – Panasonic AJ-P2C016RG User Manual

Page 160

Advertising
background image

160

Maintenance and Inspections: Warning System

If a problem is detected immediately after the power is turned on, or during operation, this will be indicated by the WARNING
lamp, lamps inside the viewfinder and a warning tone.

Note

The WARNING lamp has the highest priority, followed by the tally lamp, and then the warning tone. When multiple errors
occur simultaneously a higher priority indication will be triggered. The [WIRELESS-RF], however, may not be indicated,
depending on the menu setting.

Warning System

Warning Description Tables

1. System Errors

Display window
indication

The error code lights up.

WARNING lamp

Blinks 4 times per second.

Tally lamp

Blinks 4 times per second.

Viewfinder

The “SYSTEM ERROR” indication and
the error code light up.

Warning tone

Beeps continuously.

Warning description

An error in the reference signal or the
communication.

Recording/playback
operation

The operation stops.

Countermeasures

Please confirm [Error Codes] (page 163)
and consult your distributor.

2. Card removal error

Display window
indication

Error code “E-30” blinks.

WARNING lamp

Blinks 4 times per second.

Tally lamp

Blinks 4 times per second.

Viewfinder

The “TURN POWER OFF” indicator lights
up.

Warning tone

Continues to beep.

Warning description

The P2 card being accessed has been
removed, resulting in an error in the
internal memory of the unit.

Recording/playback
operation

Cannot be performed.

Countermeasures

Turn off the power to the unit. If there is
an error in a clip on the removed P2 card,
repair the clip.

3. Battery Empty

Display window
indication

All 7 bar indicators for battery remaining
capacity start blinking.

WARNING lamp

Lights up.

Tally lamp

Blinks once per second.

Viewfinder

The BATT LED lights up.

Warning tone

Beeps continuously.

Warning description

The battery has run out.

Recording/playback
operation

The operation stops.

Countermeasures

Replace the battery.

4. P2 Card Fully Recorded

Display window
indication

All 7 bar indicators for remaining MEDIA
capacity start blinking.

WARNING lamp

This lamp will illuminate continuously until
an operation is made after recording.

Tally lamp

This lamp will flash 4 times every second
until an operation is made after recording.

Viewfinder

The “END” indicator blinks.
When a write protected P2 card has been
inserted, the “WP” indicator lights up.

Warning tone

This tone will sound continuously until an
operation is made after recording.

Warning description

The P2 cards are recorded to maximum
capacity.

Recording/playback
operation

The recording stops.

Countermeasures

Delete the clips in the P2 card or insert a
new P2 card.

5. Image Sequence Error (24P, 30P, 25P)

Display window
indication

“E-40” appears in the time code display
field.

WARNING lamp

Blinks 4 times per second.

Tally lamp

Blinks 4 times per second while recording
continues.

Viewfinder

The “REC WARNING” indicator lights up.

Warning tone

Beeps 4 times per second while recording
continues.

Warning description

There are abnormal conditions in the
image sequence of the 24P, 30P, or 25P
mode.

Recording/playback
operation

Images can be recorded and played
back, but some frames may be dropped
or the sequences of TC and UB may shift.

Countermeasures

Confirm the recording/playback operation
after turning off the power supply once
and then turning it on again. If the error is
not corrected after executing this
procedure, contact the dealer.