To align the supply sensor with a feed aperture:

1. Pull the black indicator below the sensor adjustment knob

(see the figure below) toward you until it stops.

2. Hold a sample of the supply loaded in the printer against

the platen cover as shown in the figure. The pointer on
the indicator shows where the sensor is located on the
supply loaded in the printer.

3. While pulling the pin toward you, turn the sensor

adjustment knob until the pointer on the indicator is
aligned with the center of the feed aperture on the supply
sample.

4. Lift the front panel and snap the top corners closed.

To align the supply sensor with a black mark, turn the sensor
adjustment knob counterclockwise until it stops. Die cut
supplies require no sensor adjustment.

NOTE: The supply sensor moves at the rate of 35 complete

turns (of the sensor adjustment knob) per inch.