ViewStation User’s Guide

Symptom

Cause

Solution

IMUX 512 (Inverse Multiplexer)

Cannot dial remote

system in BONDING

384K calls

Call progress circles only

show blue or yellow.

Start by calling the far-site at 1x64 or

2x64K. This will verify if the primary

number is correct. If these calls complete, try

256K then 384K.

Dialing a remote site in

calls above 128K does

not work.

Call progress circles do not

turn green, or remain blue

after the first channel

connects.

Go to the call status screen. Highlight each

of the circles for each of the channels dialed.

The number dialed for each channel will be

displayed as you highlight the

corresponding circle. Make sure that the far-

site has entered the number for each of their

ISDN lines correctly. The numbers for Line 1

- Line 4 should correspond with connections

1 - 4 on the IMUX.

System will not start.

System restarts over and over

again.

Defective cable between the IMUX and

ViewStation. Check that the green lights on

each ISDN card are on and that the green

light on the top of the IMUX is on (red on

older units). The cable from the IMUX to the

ViewStation is a straight RJ-45 x RJ-45 cable.

Bad power supply.

Cannot select 112 or 128

speeds for BONDING

calls from the speed

selection icon on the

Video Phone.

Speeds do not show when

selecting the speed icon.

Add line speeds by going to the IMUX

Dialing Speeds screen.

LAN/Intranet

Cannot access

ViewStation from your PC

browser.

DHCP Client is ON and no

DHCP server is available.

Contact your network administrator.

LAN cable is connected to the

PC port.

Connect the LAN cable to the LAN port on

the rear of the ViewStation.

Bad LAN cable.

Check the light on the back of the

ViewStation. You should have a steady

green light to indicate a connection to the

LAN and a flashing orange light to indicate

LAN traffic.

There is a firewall between

your PC and your

ViewStation.

Consult your network administrator.

Your PC is on a different

subnet and there is router

between you and your

ViewStation.

Change your PC or ViewStation Subnet

mask and IP address so that they are both on

the same LAN or subnet.

System does not allow

management via the web.

Wrong password.

Enter the correct password. Note: The

default password is “admin”.

Too many managers logged

into the system.

Only two system managers are allowed at

any one time. To log everybody else out,

restart your ViewStation.