Storage, Pump – Porter-Cable A17914-05-10-06 User Manual

Page 16

Advertising
background image

16- ENG

A17914

3. Disconnect high pressure hose

from pump and from spray gun.

4. Connect 12 inch length of hose

to water inlet of pump.

5. Add

RV

antifreeze to hose as

shown.

6. Place the ON-OFF switch in the

On position then Off position.
until an ti freeze comes out of high
pressure hose con nec tion of
pump.

7. Remove short hose from water

inlet of pump.

8. Drain all water from high

pressure hose, coil it, and store
it in cradle of the pressure washer
handle.

9. Drain all water from spray gun

and wand by holding spray gun
in a vertical position with nozzle
end pointing down and squeez ing
trigger. Store in gun/hose holder.

10. Store chemical hose, high

pressure hose, spray gun, and
wand so they are protected from
dam age, such as being run over.

It is recommended that you follow
these steps to protect the internal
seals of the pressure washer when
STORING THE UNIT FOR AN
EXTENDED PERIOD and/or WHEN
FREEZING TEMPERATURES ARE
EXPECTED. Allowing pump to
freeze will void pressure washer
warranty.

PUMP

NOTE: If storing the unit for more
than 30 days *RV antifreeze needs
to be run through the pump. This
helps pre vent dam age within the
pump head. RV an ti freeze is not only
added for winterizing, but for proper
lu bri ca tion regardless of temperature
or en vi ron ment. Storing the pump
less than 30 days in warm weather
does not require the RV antifreeze.

*Windshield washer fluid may also be

used.

1. Make sure unit is unplugged

from power source.

2. Obtain a funnel, six ounces

of RV antifreeze, and
approximately 12 inches of
garden hose with a male hose
connector attached to one end.

Risk of property
damage. Use only

RV antifreeze. Any other an ti freeze
is corrosive and can damage pump.

STORAGE