CLEARANCE TO COMBUSTIBLES

ELECTRICAL CONNECTION

A 15 AMP, 120 Volt,60Hz circuit with a properly grounded outlet
is required. Preferably, the fireplace will be on a dedicated
circuit. Other appliances on the same circuit may cause the
circuit breaker to trip or the fuse to blow when the heater is on
operation. The unit comes standard with a 6’ (1828mm) long
three wire cord exiting from the rear of the fireplace. Plan the
installation to avoid the use of an extension cord. If an extention
cord must be used, it must be a minumum 14 AWG three wire
with grounding type plug connector and rated no less than
1900 Watts.The cord shall not be more than 20 feet in length.

ELECTRICAL SPECIFICATIONS

SERVICE INSTRUCTIONS

WARNING: Disconnect power before
attempting any maintenance or clean-
ing to reduce the risk of fire, electri-
cal shock or personal injury.

REPLACING LIGHT BULBS

This fireplace uses four clear 120 Volt, 60 Watt, E-
12 socket base light bulbs (small base, chandelier
candle type).The 60 Watt bulbs are located under
the log set/ember bed. For convenience, if one of
the bulbs burns out, it may be a good idea to re-
place all of the light bulbs.

1. Turn off power to the unit by unplugging the power cord.
2. Let fireplace cool if it has been operating.
3. Remove the two screws on the top corner of screen. Pull

the screen upward slightly, and then pull out.

4. Remove the four screws that secure the log set/em-

ber bed in position.

5. Remove log set / ember bed and grate assembly.
6. Examine the bulb(s) to determine which bulbs need

to be replaced.

7. While holding the socket, unscrew defective bulb(s)

counterclockwise.

8. Install the new light bulb(s) by holding the socket and

screwing clockwise.

9. Reinstall the log set/ember bed, grate assembly and

screen. Follow the above procedure in reverse order.

WARNING: Do not exceed 60
Watts per bulb. The use of
higher rated bulbs may result
in a fire causing property
damage and personal injury.

Sides....................................0 mm 0 inches

Floor.....................................0 mm 0 inches

Top........................................0 mm 0 inches

Voltage:

120 VAC, 60 Hz

Total Amps:

11.5 Amps

Total Watts:

1380 Watts

Heater Rating:

1200 Watts

WARNING: Electrical outlet wir-
ing must comply with local build-
ing codes and all other appliable
regulations to reduce the risk of
fire, electrical shock and injury.

WARNING: Do not use this fire-
place if any part of it has been
under water. Immediatly call a
quilified service technitian to in-
spect the fireplace and replace
any part of the electrical system
if necessary.

3

LOCATING YOUR ELECTRIC FIREPLACE

Your new freestanding electric fireplace may be installed vir-

tually anywhere in your home. However when choosing a

location for your new electric fireplace, ensure that the gen-

eral instructions are followed. For best effect results, install

the electric fireplace out of direct sunlight.