MAINTENANCE OF MOTORS

The motors used on the fan and flame genera-
tor assembly are prelubricated for extended
bearing life and require no further lubrication.
However, periodic cleaning/vacuuming of the
fan/heater unit is recommended.

WARNING: Make sure that the
power is turned off before
proceeding.

GLASS INFORMATION

1. Under no circumstances should this product be

operated with missing or broken glass.

2. Do not strike or slam the glass.
3. Do not use abrasive cleaners to clean the glass.
4. Replacement glass is available from the manu-

facturer and replacement should be carried out
by a qualified service person.

ELECTRICAL WIRING DIAGRAM

Any electrical repairs or rewiring of this unit should be carried out by a licensed electrician in accordance
with national and local codes.

If repairing or replacing any electrical component or wiring, the original wire
routing, color coding and securing location must be followed.

4

Wire Gauge:

Power Cord 14AWG
Heater Element 16AWG
Other Wire 18AWG

Model: SFE23RE, SFE33RE
Voltage: 120 VAC, 60 Hz
Total Amps: 11.5 Amps
Total Watts: 1380 Watts
Heater Rating: 1200 Watts