Indicators Message

The POWER indicator, LAMP indicator and TEMP indicator light or blink in the following cases.

Table 1-9. Indicators Message list

POWER

indicator

LAMP

indicator

TEMP

indicator

Contents

Lights

orange

Turns off Turns off Standby status

Blinks

green

Turns off Turns off Warming up. Wait.

Lights

green

Turns off Turns off Operation status.

Blinks

orange

Turns off Turns off Cool down.

Lights

red

Lights

red

Turns off

The lamp does not light.
Wait some time (approx. 20 min.) before turning the
power on again. If the indicator still lights, the lamp may
have failed and. Replace with a new lamp.

Lights

red

Blinks

red

Turns off

A lamp has not been inserted or the lamp cover is
missing.
Cut a power source, and happen for about 45 minutes,
and confirm the condition which a ramp and a ramp
cover mount this opportunity after cooling it fully. Make
contact with the store when a power source is made ON
again after the modification and it becomes the same
display again.

Lights

red

Turns off

Blinks

red

The cooling fan is not operating.
Cut a power source, and happen for about 20 minutes,
and confirm this opportunity after cooling it whether a
foreign substance isn't caught in the fan. Make contact
with the store when a power source is made ON again
after the modification and it becomes the same display
again.

Lights

red

Turns off

Lights

red

Internal overheating. *1)
Confirm this opportunity with the air filter if you don't
become dirty or ambient air temperature doesn't exceed
35 degrees if intake mouth and an exhaust mouth aren't
occupied after cooling it cut a power source it happens
for about 20 minutes. Make contact with the store when a
power source is made ON again after the modification
and it becomes the same display again.

*1) In some cases, when the air holes becomes blocked and the interior temperature rises,
the lamp will be turned off for protection and the LAMP indicator will flash red. In such
cases, turn off the MAIN POWER switch, allow the set to cool (for approx. 20 min.) and
then turn the power on again.