English – Pentair INTELLIFLO VS-3050 User Manual

Page 14

Advertising
background image

14

Section 3

User Maintenance

The following information describes how to service and maintain the IntelliFlo

®

pump.

Pump Strainer Basket

The strainer, sometimes referred to as the “Hair and Lint Pot,” is in front of the of the pump. Inside

there is a basket which must be kept clean of leaves and debris at all times. View the basket through

the top see through lid to inspect for leaves and debris.
Regardless of the length of time between filter cleaning, it is most important to visually inspect the hair and lint

pot basket at least once a week. A dirty basket will reduce the efficiency of the filter and possibly the heater.

WARNING —

DO NOT open the strainer pot if pump fails to prime or if pump has been operating

without water in the strainer pot. Pumps operated in these circumstances may experience

a build up of vapor pressure and may contain scalding hot water. Opening the pump may

cause serious personal injury. In order to avoid the possibility of personal injury, make

sure the suction and discharge valves are open and that the strainer pot is cool to the

touch, then open with extreme caution.

CAUTION —

To prevent damage to the pump and filter and for proper operation of the system, clean
pump strainer and skimmer baskets regularly.

Pump Strainer Basket Service

If the IntelliFlo

®

pump is installed below the water level of the

pool, close the return and suction lines before opening the hair

and lint pot on the pump.
1. Press the Stop button to stop the pump and switch off the

pump at the circuit breaker.

2. Relieve pressure in the system.
3. Turn the clamp and lid in a counterclockwise direction until

it stops.

4. Remove the clamp and lid.
5. Remove the basket and put the debris into the trash and rinse

out the basket. If the basket is cracked, replace the basket.

6. Replace the basket and fill the pump pot and volute with

water up to the inlet port.

7. Clean the cover, o-ring, and sealing surface of the pump pot.

Grease the o-ring with Teflon or silicone lubricant.

8. Reinstall the lid by placing the clamp and the lid on the pot.

English