English, Drive assembly removal and installation – Pentair INTELLIFLO VS-3050 User Manual

Page 21

Advertising
background image

21

Drive Assembly Removal and Installation

To remove the IntelliFlo

®

drive and control panel from the motor assembly:

1. Make sure all electrical breakers and switches are turned off before removing the drive.
2. Open the control panel cover.
3. Remove the three Phillips head screws securing the drive to the motor assembly as shown.

CAUTION: TO AVOID ELECTRICAL HAZARD, DO NOT REMOVE THE FOUR TAMPER

PROOF BITS FROM THE MOTOR ASSEMBLY

4. Lift up the drive assembly and remove it from the motor adapter located on top of the motor assembly.
Note: Be careful not to remove the gasket between the drive and motor, it is critical in keeping

moisture out of the drive and motor. Replace the gasket if damaged. Do not reassemble with a

damaged or missing gasket.

To install the IntelliFlo

®

drive assembly onto the motor assembly:

1. Make sure all electrical breakers and switches are turned off before installing the drive.
2. Be sure that the gasket between the drive and motor is in place. It is critical in keeping moisture

out of the drive and motor. Replace the gasket if damaged. Do not reassemble with a damaged or

missing gasket.

3. Verify that the three (3) orange motor post caps are in position before placing the drive on the

motor assembly.

4. Align the drive assembly with the motor adapter and seat the drive on the motor assembly.
5. Secure and tighten the drive assembly with the three Phillips head screws.

Phillips head screws

Phillips head screw

Do not remove

these screws

Adapter connector

Gasket

Orange motor post

caps (QTY. 3)

English