19

19. TREBLE Gain Data

Function
The external control equipment changes the TREBLE gain data of the plasma monitor.
Transmission Data

DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS

DATA00 : USER PICTURE Gain Flag

05H

DATA01 : TREBLE Gain Flag

04H

DATA02 : TREBLE Gain

F3H : -13

:

FFH : -01

00H : 0

01H : +01

:

0DH : +13

ACK

7FH 60H 80H 7FH 02H DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

05H

DATA01: TREBLE Gain Flag

04H


20. BALANCE Gain Data

Function
The external control equipment changes the BALANCE gain data of the plasma monitor.
Transmission Data

DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS

DATA00 : USER PICTURE Gain Flag

05H

DATA01 : BALANCE Gain Flag

02H

DATA02 : BALANCE Gain

EAH : -22

:

FFH : -01

00H : 0

01H : +01

:

16H : +22


ACK

7FH 60H 80H 7FH 02H DATA00

DATA01 CKS

DATA00: USER PICTURE Gain Flag

05H

DATA01: BALANCE Gain Flag

02H


1. SCREEN SIZE Select

Function
The external control equipment switches the screen mode of the plasma monitor.
Transmission Data

DFH 80H 60H 51H 01H DATA00 CKS

DATA00 02H : WIDE

03H : ZOOM

04H : STD

05H : FULL

06H : DOT BY DOT

08H : UNDERSCAN

09H : 14:9