21

22. V.POSITION Gain Data

Function
The external control equipment changes the V. POSITION gain data of the plasma monitor.
Transmission Data

DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS

DATA00 : USER PICTURE Gain Flag

03H

DATA01 : V.POSITION Gain Flag

01H

DATA02 : V.POSITION Gain

C0H : -64

:

FFH : -01

00H : 0

01H : +01

:

40H : +64

ACK

7FH 60H 80H 7FH 02H DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

03H

DATA01: V.POSITION Gain Flag

01H