Pdp-614mx external control manual – Pioneer PDP-614MX External Control Manual RS-232C User Manual

Page 22

Advertising
background image

PDP-614MX External Control Manual

22

23. H.POSITION Gain Data

Function
The external control equipment changes the H. POSITION gain data of the plasma monitor.
Transmission Data

DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS

DATA00 : USER PICTURE Gain Flag

03H

DATA01 : H.POSITION Gain Flag

02H

DATA02 : H.POSITION Gain

80H : -128

:

FFH : -01

00H : 0

01H : +01

:

7FH : +127

ACK

7FH 60H 80H 7FH 02H DATA00 DATA01

CKS

DATA00: USER PICTURE Gain Flag

03H

DATA01: H.POSITION Gain Flag

02H



24. V.SIZE Gain Data

Function
The external control equipment changes the V.SIZE gain data of the plasma monitor.
Transmission Data

DFH 80H 60H 7FH 03H DATA00 DATA01 DATA02 CKS
DATA00 : USER PICTURE Gain Flag

03H

DATA01 : V.SIZE Gain Flag

07H

DATA02 : V.SIZE Gain

00H : 0

:

40H : +64

ACK

7FH 60H 80H 7FH 02H DATA00 DATA01 CKS

DATA00: USER PICTURE Gain Flag

03H

DATA01: V.SIZE Gain Flag

07H

Advertising
This manual is related to the following products: