Auto id set start, Pdp-614mx external control manual – Pioneer PDP-614MX External Control Manual RS-232C User Manual

Page 54

Advertising
background image

PDP-614MX External Control Manual

54

67. AUTO ID SET START

Function
External control apparatus sets up ID automatically to two or more plasma monitors.
Transmission Data

5FH 80H 60H F0H 01H DATA00 CKS

DATA00 00H~FFH: ID of a master

*1

is set up.


*: When you use it by the multi-system, please remove the link input of a master

*1

.

*1: “Master” means the 1st set of PDP at the time of cable connection at the time of AUTO ID execution.

68. PLE LINK

Function
External control apparatus sets up equally PLE between two or more plasma monitors.
Transmission Data

DFH 80H 60H F1H 03H DATA00 to DATA02 CKS

DATA00 00H:PLE LINK ON

01H:PLE LINK OFF

DATA01 FFH(fixed)
DATA02 FFH(fixed)

*:Turn on the AUTO ID and set the DIVIDER(at 1,4 or 9), before this operation

69. VIDEO WALL SETTING

Function

External control apparatus sets 4screens or 9screens as a video wall.

Transmission Data

DFH 80H 60H F3H 03H DATA00 DATA01 DATA02 CKS

DATA00:

01H:1 screen

(Matrix diplay function does not work.)

04H:4 screens (2*2 video wall)
09H:9 screens (3*3 video wall)

DATA 01:

00H(fixed)

DATA 02:

01H : Video1

02H : Video2

03H : Video3

04H : COMPNT1

05H : COMPNT2

06H : COMPNT3

07H : PC1DSUB

08H : PC2-BNC

09H : PC3-DVI

*:Turn on the AUTO ID, before this operation
*: This command is used to following system.
1. The system configuration is video wall system (4screens or 9screens).
Then please connect each PDP by wired cable.

In the case of 16 screens or 25 screens video wall system, please refer to No.65.”MULTI MODE Select”.

2. The ID number from a master display is set the continuous number.