Profoto Pro-B2 User Manual

Page 12

Advertising
background image

obtained is chosen with the control POWER [15,16]. If the lamp head is connected to B half

the energy is obtained if the SYM/ASYM switch is in position A 1/1 (1/2), B 1/2. If the switch

is in the position A 1/2, B 1/4 a quarter of the chosen energy is obtained. Two lamp heads:

The energy chosen with the POWER [15,16] control can either be distributed evenly through

the two lamp heads (the SYM/ASYM switch in the position A1/1 (1/2), B 1/2) or twice

as much energy (equivalent to one f-stop ratio) through A as B (the SYM/ASYM switch

in the position A 1/2, B 1/4). At any change of energy with the control POWER [15,16 ]

the ready lamp [8] is put out. When the light is out, this is an indication that auto dumping

or recharging is in progress.

Choice of Modelling Light

First set the MOD.LIGHT (13) to timer controlled or continuous The maximum modelling

light is 250 W even if a ProHead/ProTwin with a 500 W halogen lamp is used. A ProHead or

older heads - Pro-7, PB or PF - can be used. The modelling light is automatically dimmed

down to max 2500 W regardless of the nominal effect of the modelling light. The efficiency

(output) is higher when using a 100 or 250 W lamp. We therefore recommend using max

250 W lamps also in the ProHead. The modelling light is constant and does not vary with the

energy chosen. If you wish to use a 250W lamp the ProHead or proTwin flash head must be

used since the built-in fan will work on Pro-B2. Do not use older heads with a 250W lamp.

Timer controlled

Pushing the button MOD.LIGHT [11] turns on the modelling light. To save the battery the

modelling light is automatically turned off after 10 seconds or when triggering a flash.

To have the modelling light stay on for a longer period of time push the button two or three

consecutive times, which will give 30 and 60 seconds respectively. For every period of

20 seconds when the modelling light is turned on the battery capacity decreases by the

equivalent of two flashes at full energy.

Instructions

Pro -B2

The Light Shaping Company

23

Profoto

Changing Battery

xxxxxxxxxxxxxxxxxxxx

By putting the two handles at the bottom together the battery

cassette is released and the battery can easily be pulled out. A new

battery is pushed all the way into the generator and is locked by

directing the handles away from each other. When changing the

battery it must be mounted in a battery cassette by an authorised

service station.

Connecting Lamp Heads

One or two lamp heads can be connected to the lamp head sockets

A & B [1]. When connecting the lamp head plug, align the dots

on the plug with the white dot on the generator panel. Secure by

turning the locking ring on the plug clockwise.

Energy Control

The energy output is regulated over eight f-stops. The energy can

partly be adjusted with the control POWER [16] in 1/2 f-stop

increments, from 1/1 down to 1/16 of the total energy

(equivalent to five f-stops) and also via the POWER dial (15) for

fine-grained energy control in 1/10 f-stop increments and partly

with the SYM/ASYM switch [2] and through the use of one or

two lamp heads.

One lamp head: The total energy chosen is obtained if the

lamp head is connected to A and the SYM/ASYM switch

is at A 1/1(1/2), B 1/2. The lamp head can be connected

to socket A or B. If the lamp head is connected to A the

total energy

Pro -B2

Instructions

[1]

[16]

[15]

[8]

[11]

[13]

Profoto

22

The Light Shaping Company

Advertising