Powermatic WP2510 User Manual

Page 22

Advertising
background image

22

SINGLE MODE

In single mode, the device performs automatic positioning of the table to the
programmed target position. The “Table Up” or “Table Down” button on the planer
should be pushed and held; when the table has fully adjusted to the target position, the
table will automatically stop in position. Release the push button.

Setting Target Value

Step 1: Press

(Target window LED starts blinking)


Step 2: Enter the target value using numerical keypad.

Step 3: Press

to complete.

LED lamp starts blinking – the device is ready to start the positioning.



Start/Stop/Cancel

Press

to start the positioning. The LED lamp now stops blinking and remains

on during the procedure.

Press

to cancel the positioning. The LED lamp is turned off.

If the

key is pressed while the positioning is running, the procedure is

interrupted, the machine is stopped, and the

LED is turned off. To repeat the

positioning of the same target, press

.



To program another target value, press

- enter new value -

.



Advertising