Drive-related errors – Promise Technology 150TX2 User Manual

Page 63

Advertising
background image

Chapter 6: Troubleshooting & Tips

59

Drive-Related Errors

Critical Array Status Error Reported during Boot

If a critical status error message appears on the FastTrak S150 TX2plus BIOS
startup screen for a mirrored array (see below), there is a drive in the array that
has failed or is not responding. FastTrak S150 TX2plus will identify the failed
drive by channel number. The mirrored array has lost its fault tolerance, but will
still perform normal drive reads and writes.


Operation aborted because FastBuild encountered an error as
follows:

Location:

Channel

2

Array Status: Critical


Please retry using Promise Array Management utility to recover all
data. Reboot the system by pressing the ENTER key.

Try powering the system off and on to reset the drive. Also confirm that cables
are properly attached and the drive is receiving power. If the drive still appears
to have failed, refer to the Rebuilding an Array option in the Promise Array
Management (PAM) utility as detailed in the PAM User Manual.

Drive cannot be formed into an array

Drives must support Ultra DMA or Serial ATA and be free of media defects to be
added into an array. Promise recommends using new identical drives for each
array. Re-secure data and power cabling while checking for proper alignment.
Typically, Pin 1 of the drive is closest to the power connector.

System CMOS displays C: or D: drive failure during Startup

Do not reference C: or D: in the Motherboard Standard CMOS for drives
attached to the FastTrak S150 TX2plus controller. Only enter drive information
in the Motherboard CMOS for drives attached to the onboard IDE controller.

FDISK reports a much lower drive capacity if a single physical drive or a
striped array exceeds 64GB

Due to a limitation with FDISK, the utility reports only the storage capacity that
exceeds 64GB. This is a cosmetic, not actual, limitation. Simply create a single
DOS drive partition, reboot, and then format the partition. The Format command
will recognize the total capacity of the partition accurately. Windows NT/2000/98
will now recognize the total capacity of your array.