PUR Water Purification Products Air Filter User Manual

Page 7

Advertising
background image

5.3

TO REPLACE THE SWEATBAND

The Primair Series headgear comes with a replaceable sweat band. To replace the sweatband:
1.

Peel the old sweatband off the headgear.

2.

Using a mild cleaning solution and a cloth or sponge, remove any excess adhesive that may remain on the headband. Rinse in
clean water than air dry in a clean area before attaching the replacement sweatband

3.

Remove the protective backing of the replacement sweatband (P/N PA104) and press it onto the headgear (figure 9).

6 CLEANING

AND

SANITIZING

The headgear should be cleaned and sanitized between use.
Remove the head cover from the headgear.
Clean the headgear by using a mild cleaning solution and a cloth or sponge. Rinse in clean water than air dry in a clean area.
Visually inspect all components for damage and replace the entire headgear if any component is damaged.
Put the replacement head cover on the headgear (see 2.2 of these User Instructions).

7

STORAGE

Store the Primair headgear at room temperature in a clean dry area, away from direct sunlight and sources of direct heat.

8

MAJOR COMPONENTS

PA101S

Headgear with head cover, Primair loose fitting facepiece, Size Small

PA101M

Headgear with head cover, Primair loose fitting facepiece, Size Medium

PA101L

Headgear with head cover, Primair loose fitting facepiece, Size Large

PA111

Headgear with head cover, Primair Plus Hood, Tyvek QC

PA121

Headgear with head cover, Primair Plus Hood, Saranex coated Tyvek

9

PRIMAIR REPLACEMENT PARTS

PA102S

Replacement head cover, Primair loose fitting facepiece, Size Small

PA102M

Replacement head cover, Primair loose fitting facepiece, Size Medium

PA102L

Replacement head cover, Primair loose fitting facepiece, Size Large

PA112

Replacement head cover, Primair Plus Hood, Tyvek QC

PA122

Replacement head cover, Primair Plus Hood, Saranex coated Tyvek

PA104

Replacement Sweatbands

10

CARTRIDGES AND FILTERS

40HE

High Efficiancy Particulate Air-Purifying (HEPA) Filter

4001

Organic Vapor (OV) Cartridge

4001HE

Organic Vapor / HEPA (OV/HE) Filter Cartridge Combination

4003

Organic Vapor / Acid Gas (OV/AG) Cartridge

4003HE

Organic Vapor / Acid Gas / HEPA (OV/AG/HE) Filter Cartridge Combination

4004

Ammonia / Methylamine (AM/MA) Cartridge

4004HE

Ammonia / Methylamine / HEPA (AM/MA/HE) Filter Cartridge Combination

7

CAUTION

Be sure the air duct (manifold) is completely dry inside as well as outside before reusing the respirator or s
ealing the headgear in a bag for storage. Forcing air through the air duct for a few minutes using the
Compact Air blower battery assembly can help assure that all moisture has been removed from the inside of
the air duct.

CAUTION

Do not use liquid solvents when cleaning the headgear. Liquid solvents may chemically weaken the plastic

E

E

N

N
G

G

L

L

II

S

S

H

H

Advertising