Configuring SNMP Traps and Trap Dial-Out

Select SNMP Traps from the Management and Communication menu to
configure SNMP traps and dial-out when a trap is generated (see Table 3-14).

Main Menu

Configuration

Management and Communication

SNMP Traps

See Appendix B,

SNMP MIBs and Traps, and

RMON Alarm Defaults

, for trap

format standards and special trap features, including RMON-specific traps, and
the default settings that will generate RMON-specific SNMP traps.

Table 3-14.

SNMP Traps and Trap Dial-Out Options (1 of 5)

SNMP Traps

Possible Settings: Enable, Disable
Default Setting: Disable

Determines whether the FrameSaver unit sends trap messages to the currently
configured SNMP trap manager(s).

Enable – Sends trap messages.

Disable – Does not send trap messages.

Number of Trap Managers

Possible Settings: 1 – 6
Default Setting: 1

Specifies the number of SNMP management systems that will receive SNMP trap
messages from the FrameSaver unit. An NMS IP Address must be configured in the
NMS

n IP Address configuration option for each trap manager to receive trap

messages.

1 – 6 – Specifies the number of trap managers (inclusive).

NMS

n IP Address

Possible Settings: 001.000.000.000 – 223.255.255.255, Clear
Default Setting: Clear (000.000.000.000)

Specifies the IP address that identifies the SNMP manager(s) to receive SNMP traps.

Display Conditions – This option appears for each trap manager specified in the
Number of Trap Managers configuration option.

001.000.000.000 – 223.255.255.255 – Adds to or changes the IP address for the trap
manager.

Clear – Fills the NMS IP address with zeros.