Technical data – Parkinson Cowan SONATA 50GX User Manual

Page 35

Advertising
background image

TECHNICAL DATA

DIMENSIONS

Height Width Depth

Height to hotplate

907mm (nominal) 500mm (nominal) 603 mm

(to front of
door panel)

Space for fixing at hotplate level

2mm minimum clearance

Minimum space above hotplate 787mm (If a cooker hood is fitted refer to thecookerhood
installation instructions).
Space for fixing above hotplate level See important note "Location of Appliance", page 37.
Weight of appliance 48.4kg.
Minimum distance from rear wall 5mm (spacer given by pressed spacer on vent panel).

CONNECTIONS

Gas Rear left hand side of appliance at hotplate level.
Rc½ (½" B.S.P. female).
Electric None

IGNITION

Spark generator APCO 7BG 6893
Battery 1.5 Volt AA size

GRILL

Natural Gas

L.P. Gas

Heat Input 3.3kW (11263 Btu/h) 3.0kW (215g/h)
Injector Marking

138 88

HOTPLATE

Natural Gas

R.H.F. R.H.R. L.H.R. L.H.F
Heat Input 1.0kW 2.0kW 2.0kW 2.8kW

(3412 Btu/h) (6824 Btu/h) ( 6824 Btu/h) (9554 Btu/h)

Injector Marking

079

104

104

130

L.P.Gas

Heat Input1 1.0kW 2.0kW 2.0kW 2.7kW
(71.8 g/h) (143.7 g/h) (143.7 g/h) (194.0 g/h)
Injector Marking 051 072 072 083

35