LOCATION OF APPLIANCE

This appliance must not be installed in a bed-sitting room of volume less than 20m³ or in a bathroom or
shower room. It is essential that the appliance is positioned as stated below (see Fig. 1) i.e. shelves, wall
cabinets and cooker hoods must be fitted a minimum of 787mm directly above the top of hotplate and
400mm above the hotplate when fitted in line with the outside of the appliance. If the units are intended to
be fitted adjacent to the appliance but less than 400mm above the hotplate, then a minimum space of
100mm must be maintained between the sides of the unit and the appliance (see Fig.2). Curtains must not
be fitted immediately behind the appliance or within 150mm of the sides of the hotplate. If fitted next to or
between two base units a minimum space of 1mm must be left between each unit and the sides of the
appliance. The hotplate must be set to minimum of 7mm above the adjacent units. (Note: The levelling feet
fitted to the appliance will achieve a nominal height of 907mm -5+13mm). Base units not meeting the
above conditions must be a minimum of 100mm away from the hotplate. L.P.G. cookers MUST NOT be
installed below ground level, i.e. in a basement.


Fig.1a All dimensions in mm Fig.1b

INSTALLATION

1. PARTS REQUIRED

The loose hotplate parts and battery are packed in the polystyrene fitment on top of the hotplate.