With kx-t7600 series dpt – Panasonic HYBRID IP-PBX KX-TDA50 User Manual

Page 91

Advertising
background image

2.6 Connection of Extensions

Installation Manual

91

2.6.3

Digital EXtra Device Port (Digital XDP) Connection

A DPT can be connected to another DPT on the Digital XDP connection. In addition, if the DPT is connected
to a Super Hybrid Port, it can also have an SLT connected in Parallel mode or XDP mode.

Notes

Both DPTs must be KX-T7600 series DPTs (except KX-T7640). Note that the KX-T7667 can only
be connected as a slave DPT.

Parallel mode or XDP mode can be selected through system programming.

If XDP mode is enabled through system programming, parallel connection is not possible. Refer to
"1.13.2 Paralleled Telephone" and "1.5.7 Extension Port Configuration" in the Feature Manual for
further information.

With KX-T7600 Series DPT

Using a Modular T-Adaptor

To DLC4/DLC8 card

To a Super Hybrid Port

(for connection of SLT)

4-conductor wiring cord
Connect pins "D1" and "D2".

Slave DPT

SLT

Master DPT

Modular
T-Adaptor

4-conductor wiring cord
Connect pins "D1" and
"D2".

2-conductor wiring cord
Connect pins "T" and "R".

Slave DPT

Master DPT

TO MAIN UNIT

/ PABX

TO TEL

TO MAIN UNIT
/ PABX

Cable

Maximum Distance

26 AWG: 30 m (98 ft)
24 AWG: 50 m (164 ft)
22 AWG: 60 m (196 ft)
CAT 5:

50 m (164 ft)

Back View of DPTs

To DLC4/DLC8 card

To a Super Hybrid Port
(for connection of SLT)

Advertising