4)

Timing

The timing from the receipt of a command to the return of the status value is
as follows:

• T1 is the time from the receipt of <C/R> at the end of the command string to

the start of command execution, and is within a maximum of 20 ms.

• T2 is the command execution time, and is at least 14 ms.

T2 (before the <C/R>) increases depending on the type of command.

• The minimum processing time for any command (total of T1 and T2) is 14 ms.

Chapter Four • CLD-V2600 / 2400 Level I & III

Figure 4-G

Timing Diagram

TxD

<CR>

<CR>

R

T1

T2

Execution

4-10

TP 117

v. 2.0

• 12/93

CLD-V2600 / 2400 Level I & III User’s Manual

T1

20 ms

T2

14 ms