Error information page, Using web browser control – Panasonic DLP PT-D3500U User Manual

Page 50

Advertising
background image

50

Using Web Browser Control

Error information page

When

is displayed on the status information screen, click it to display the error details.

OK: Normal operation

FAILED: Occurrence of trouble

When [FAILED] has appeared for an item

Parameter

MAIN CPU BUS

FAN

OPTICS MODULE

TEMPERATURE

INPUT AIR TEMPERATURE

AROUND LAMP

TEMPERATURE

LAMP REMAIN TIME

LAMP STATUS

SHUTTER

OPTICS MODULE TEMP.SENSOR

INPUT AIR TEMP.SENSOR

BATTERY

COLOR WHEEL

Description

Trouble has occurred in the microcomputer circuitry. Consult your dealer.

Trouble has occurred in the fan or its drive circuit. Consult your dealer.

The temperature inside the projector is high. It may be that the projector is

being used where the ambient temperature is high such as near a heating

appliance.

The input air temperature is too high. It may be that the projector is being

used where the ambient temperature is high such as near a heating

appliance.

The temperature near the lamp has risen very high.

Something may be blocking the exhaust vent.

The lamp runtime has exceeded the prescribed cumulative time, and it is

now time to replace the lamp.

The lamp has failed to light.

Wait a short while for the lamp to cool off, and then turn on the power.

Trouble has occurred in the shutter circuitry. Consult your dealer.

Trouble has occurred in the temperature detection sensor inside the

projector. Consult your dealer.

Trouble has occurred in the sensor used to detect the input air temperature.

Consult your dealer.

The backup battery has been run out. Consult your dealer.

Trouble has occurred in the color wheel or the color wheel drive circuit.

Consult your dealer.

• Depending on the nature of the error, the projector may be placed in the standby mode for its own

protection.

Note

Advertising