Contents of mail sent, Adjust clock page, Using web browser control – Panasonic DLP PT-D3500U User Manual

Page 54

Advertising
background image

54

Using Web Browser Control

Contents of mail sent

• Mail with the contents shown below is sent when the E-mail

settings have been established.

Adjust clock page

Click [Network set up], then [Adjust clock] to display the Adjust clock page.

• Mail with the contents shown below is sent

when an error has occurred.

Subject: Panasonic projector report(CONFIGURE)

=== Panasonic projector report(CONFIGURE) ===
Projector Type : D3500

––––– E-mail setup data –––––
TEMPERATURE WARNING SETUP
MINIMUM TIME at [ 60] minutes interval
INPUT AIR TEMPERATURE Over [ 45C / 113F ]

ERROR

[ ON ]

LAMP RUNTIME

[ OFF ] at REMAIN [ 0] H

LAMP RUNTIME

[ OFF ] at REMAIN [ 0] H

INPUT AIR TEMPERATURE [ OFF ]

PERIODIC REPORT
Sunday [ OFF ] Monday [ OFF ] Tuesday [ OFF ] Wednesday [ OFF ]
Thursday [ OFF ] Friday [ OFF ] Saturday [ OFF ]

00:00 [ OFF ] 01:00 [ OFF ] 02:00 [ OFF ] 03:00 [ OFF ]
04:00 [ OFF ] 05:00 [ OFF ] 06:00 [ OFF ] 07:00 [ OFF ]
08:00 [ OFF ] 09:00 [ OFF ] 10:00 [ OFF ] 11:00 [ OFF ]
12:00 [ OFF ] 13:00 [ OFF ] 14:00 [ OFF ] 15:00 [ OFF ]
16:00 [ OFF ] 17:00 [ OFF ] 18:00 [ OFF ] 19:00 [ OFF ]
20:00 [ OFF ] 21:00 [ OFF ] 22:00 [ OFF ] 23:00 [ OFF ]

––––– check system –––––
MAIN CPU BUS

[

OK

]

FAN [

OK

]

OPTICS MODULE TEMPERATURE

[

OK

]

INPUT AIR TEMPERATURE

[

OK

]

AROUND LAMP TEMPERATURE

[

OK

]

LAMP REMAIN TIME

[

OK

]



Subject: Panasonic projector report(ERROR)

=== Panasonic projector report(ERROR) ===
Projector Type : D3500

––––– check system –––––
MAIN CPU BUS

[

OK

]

FAN [

OK

]

OPTICS MODULE TEMPERATURE

[

OK

]

INPUT AIR TEMPERATURE

[

OK

]

AROUND LAMP TEMPERATURE

[

OK

]

LAMP REMAIN TIME

[

OK

]

LAMP STATUS

[ FAILED ]

SHUTTER

[

OK

]

OPTICS MODULE TEMP.SENSOR

[

OK

]

INPUT AIR TEMP.SENSOR

[

OK

]

AROUND LAMP TEMP.SENSOR

[

OK

]

BATTERY

[

OK

]

COLOR WHEEL

[

OK

]

(Error code 00 40 00 00 00 00 00 00)

Input air temperature

: 27 degC / 80 degF

Optics module temperature : 65 degC /149 degF
Around lamp temperature

: 27 degC / 80 degF

SET RUNTIME

1857 H

POWER ON

248 times

LAMP ON

177 times

LAMP LOW

0 H

LAMP HIGH

68 H

LAMP REMAIN

1432 H

––––– Network configuration –––––
IP address 192.168.0.8
MAC address 00:00:00:00:00:00
Wed Jan 26 18:54:31 2005
––––– Memo –––––

Time zone selection

Button to update time zone
setting

Button to update time and
date settings

New date field

New time field

• If the time becomes incorrect immediately after setting the correct time, then the battery needs to

be changed. Contact the dealer where you bought the projector to have the battery changed.