Event Log

The software is able to detect a variety of events. The event

log holds a maximum of 30 events. After the log reaches 30

events, older events are erased to make room for newer ones.
Note: There is a shortcut for quick access to the Event Log

report. From the Welcome banner, press

Reset (Pause/Reset

on tread consoles)

for five seconds. If there are no events, the

words

STUCK KEY appear and then the console returns to

the Welcome banner.
Each event log entry contains the following information:

Event number

Odometer value when the event occurred

Hour meter value at the time the event occurred

Current drawn by the motor when the event occurred

(treadmill only)

The following table contains a list of events detectable by the

software.

Table 2. Event log numbers and descriptions

Event

Number

Description of Event

00

Upper PCA memory location event

02

RAM location event

03

EEPROM checksum event

05

Depressed key at power up

09

Lower PCA memory test event

10

Line Frequency out of acceptable range

11

Watchdog (Upper PCA) low voltage power

12

Watchdog (Lower PCA) low voltage power

13

Fan at incorrect speed (version 1 treadmills)

14

Fan fail (Lower PCA)

15

AC input voltage too high

16

AC input voltage too low

20

Too many maximum power requests in one second

21

Too many maximum consecutive power requests