Data synchronization – PSC Scanners User Manual

Page 66

Advertising
background image

60

User’s / Programming Guide

Data Synchronization

Your PSC scanner can be prepared to synchronize the transmission of
scanned data to the timing sequence some terminals require to prop-
erly receive the data. This relationship is diagrammed in Figure 2.

Figure 2. Timing Sequence Diagram

RTS output is used for the data synchronization signal. Scan XD to
enable the data synchronization signal. Scan Option XC to disable
Data Synchronization.

XC

Disable Data # Synchronization

XD

Enable Data Synchronization

Polarity may be selected as either active high or low by scanning XE
(high) or XF (low).

Data Transmission

data

white space

(ta)

(th)

Active

Data Synchronization

Setup Time (ts) 200 ms - 220 ms

Hold Time (th) 0 ms - 10 ms