Connecting the power supply, Connecting a magnetic stripe reader, Terminal power-up sequence – PSC Scanners User Manual

Page 9

Advertising
background image

06656

3

Connecting the Power Supply

If supplied, plug the connector from the external power supply into
the receptacle located on the housing connector. Then plug the power
supply into a power source.

Connecting a Magnetic Stripe Reader

If a detached Magnetic Stripe Reader (MSR) is to be used, plug the
connector into the MSR receptacle located on the housing connector.

Terminal Power-Up Sequence

Turn on the power to the terminal to which the PSC scanner is con-
nected. The unit will issue a series of beeps which are intentional and
indicate that the terminal/keyboard power-on reset routines have
been completed.

Programming for Terminal Type

Proceed as follows:

1.

Using the Keyboard Wedge Parameters menu given in the
Keyboard Wedge Parameters Section scan:

WEDGE MODE ENABLE (CE)

This sets the PSC scanner into a Keyboard Wedge interface
mode.

2.

Select the terminal type by next scanning the appropriate
symbol for your terminal.

NOTE

If this is a first-time installation, it is NECESSARY to pro-
gram the PSC scanner for use with the connected termi-
nal.

NOTE

Scanning Reset to Default (ZA) will cause the PSC scan-
ner to revert to Keyboard Wedge mode with a PC-AT termi-
nal type.