otaid

string

Name or ID of the ’ota-setting’

group in Kannel configuration
that should be sent to the phone.
This variable is optional. If it is
not given the first ’ota-setting’
group is sent. This is unnecessary
when a XML document is
sended to the phone.

username

string

Username of the ’sendsms-user’

group in Kannel configuration,
that has been configured to send
OTA messages.

password

string

Password associated with given

username

. Must match

corresponding field in
’sendsms-user’ group in Kannel
configuration, or ’Authorization
failed’ is returned.

to

number

Number of the phone that is to

receive the OTA configuration
message.

from

string

Phone number of the sender.

This field is usually overridden
by the SMS Center, or it can be
overridden by faked-sender
variable in the sendsms-user
group. If this variable is not set,
smsbox global-sender is used.

smsc

string

Optional virtual smsc-id from

which the message is supposed
to have arrived. This is used for
routing purposes, if any denied
or preferred SMS centers are set
up in SMS center configuration.
This variable can be overridden
with a

forced-smsc

configuration variable. Likewise,
the

default-smsc

variable can

be used to set the SMSC if it is
not set otherwise.

text

XML document

An URL encoded XML

document, containing either
settings or bookmarks.

type

string

Type of the XML document,

either "settings" or "bookmarks".
Default is "settings".