Performance, Engineering data model rnc120f, Thermally conductive, patented aluminum core – Lifebreath RNC120F User Manual

Page 2: Motors and blowers, Filters, Mounting the hrv, Defrost, Case, Controls, Hrv system control

Advertising
background image

2

3

2

1

20

40

60

80

100

120

140

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

Static Pressure (in w.g.)

A

ir

Flow (

c

fm

)

3 - High Speed
2 - Medium Low Speed
1 - Low speed

Engineering Data

Model RNC120F

THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE

The cross-flow heat recovery core transfers heat between the two airstreams. It is easily
removed for cleaning or service.

MOTORS AND BLOWERS

Each Air stream has an independent motorized impeller. 3 speed operation 120VAC

FILTERS

Washable air filters in exhaust and supply air streams.

MOUNTING THE HRV

Four threaded inserts at corners of case designed to accept four reinforced polyester
straps that are supplied with the unit.

DEFROST

Fan defrost system. Fresh air motor turns off and Exhaust motor switches to high speed
to defrost core.

CASE

Twenty gauge prepainted galvanized steel (G60) for superior corrosion resistance.
Insulated to prevent exterior condensation. Drain connection 1 -

1

/

2

" (12 mm) OD.

CONTROLS

Unit is supplied with a remote HRV control box which can be conveniently located within
3’-0” of the HRV.

HRV System Control

HRV defaults to LOW SPEED when plugged in. HIGH SPEED option is accessible by
connecting remote controls to designated terminals inside electrical box of HRV.

Standard LOW SPEED SETTING can be increased to medium low.
Off (Standby)/Low or OFF/HIGH speed operation is also available.

DUCT CONNECTIONS

5” duct connections with “field” selectable standard airflow or reverse airflow for limited
room installations.
WEIGHT 42 lbs. (19 kg)
SHIPPING WEIGHT 45 lbs. (20.5 kg)

OPTIONAL ACCESSORIES

99-132 20 Minute Fan Timer - initiates high speed ventilation for 20 minutes. (3 wire)

20 gauge wire (min.) 100’ length

99-101 Crank Timer

99-116 Dehumidistat Ventilation Control - Dehumidistat with ON/OFF

99-130 Dehumidistat Control - Dehumidistat

99-185 Weatherhoods, Two - 5” (125mm) c/w

1

/

4

” (6mm) mesh screen

99-2040 20/40 ON/OFF Dehumidistat

WARRANTY

Units carry a lifetime warranty on the heat recovery core and a five year replacement
parts warranty.

FRESH AIR
FROM
OUTSIDE

EXHAUST
AIR FROM
BUILDING

FRESH AIR
TO BUILDING

EXHAUST AIR
TO OUTSIDE

TOP VIEW

SERVICE CLEARANCE FROM

BOTTOM OF UNIT IS MINIMUM 3'0"

9”

19”

18”

All Duct Collars are
5" diameter (127 mm)

Date: ______________________________________________

Tag: ________________________ Qty: __________________

Project: _____________________________________________

Engineer: ___________________________________________

Contractor: __________________________________________

Supplier: ____________________________________________

Quote#: ____________________________________________

Submitted by: ________________________________________

*Sensible Efficiency - thermal **Latent Efficiency - moisture

Note: Effectiveness - based on temp. differential between the 2 airstreams
Efficiency - takes into account all power inputs

Performance

Net supply air flow in cfm (L/s) against external static pressure

E.S.P

(external static pressure)

[cfm (L/s)]

@ 0.1" (25 Pa)

125 (59)

@ 0.2" (50 Pa)

120 (56)

@ 0.3" (75 Pa)

114 (54)

@ 0.4" (100 Pa)

109 (51)

@ 0.5" (125 Pa)

106 (50)

@ 0.6" (150 Pa)

99 (47)

@ 0.7" (175 Pa)

94 (44)

@ 0.8" (200 Pa)

89 (42)

Sensible Effectiveness
@ 65 cfm (30 L/s)

32°F (0°C)

72%

*Sensible Efficiency
@ 65 cfm (30 L/s)

32°F (0°C)

55%

*Sensible Efficiency
@ 65 cfm (30 L/s)

-13°F (-25°C)

45%

VAC @ 60HZ

120

WATTS / Low speed.

63

WATTS / High speed

150

Amp rating

1.5

All units conform to CSA
and UL standards.

Advertising
This manual is related to the following products: