ENGINEERING DATA

LATENT RECOVERY/MOISTURE TRANSFER CORE

The cross-flow energy recovery core transfers heat and water vapour
between the two airstreams. It is easily removed for cleaning or service.

MOTORS AND BLOWERS

- Each air stream has one centrifugal

blower driven by a common PSC motor. 5 speed fan operation.
High speed - 120 VAC, 182 Watts.

FILTERS

- Washable air filters in exhaust and supply air streams.

MOUNTING THE ERV

- Four threaded inserts at corners of case

designed to accept four PVC reinforced polyester straps that are
supplied with the unit.

DEFROST

- Damper defrost system.

CASE

- Twenty gauge prepainted galvanized steel (G60) for superior

corrosion resistance. Insulated to prevent exterior condensation.

DRAIN CONNECTIONS

- Two - 1/2” (12mm) O.D.

CONTROLS

- ControlAir 15

WEIGHT

63 lbs. (28.7 kg)

SHIPPING WEIGHT

65 lbs. (29.6 kg)

STALE AIR

TO OUTSIDE

STALE AIR

FROM HOUSE

FRESH AIR

TO INSIDE

14

3

/

4

"

(375)

19"

(483)

DIMENSIONS 200ERVD

inches (mm)

*

All Duct Connections 6"(150mm)

FILTERS

BLOWERS

*NOTE: Front clearance
of 25 inches (635 mm)
is recommended
for servicing unit.

MOTOR

31"

(787)

FRESH AIR

FROM OUTSIDE

DAMPER

DEFROST

PORT

CONDENSATE DRAINS

ENTHALPIC

CORE

OPTIONS

99-104

Digital Electronic Timer

- 20/40/60 min. (3 wire)

99-105

Deluxe Programmable Control

includes

Programmable Time Clock, Dehumidistat

and Air Sentry™

99-109

Air Sentry

™ Air Quality Monitor designed to accept

remotely mounted Control Pad.

99-186

Weatherhoods

, Two - 6” (150mm)

c/w 1/4” (6mm) mesh screen

WARRANTY

Units carry a 5 year warranty on the energy recovery core and
replacement parts.

All units conform to CSA and UL standards.

ERVs are not recommended for regions where the
design temperature is below 25°F (-4°C)

TI-200ERVD

0105

DATE: __________________________

PROJECT: __________________________________________

MECHANICAL CONTRACTOR: _____________________________

511 McCormick Blvd.

London, Ontario

N5W 4C8

Ph: (519) 457-1904
Fx: (519) 457-1676
Email: [email protected]
Website: www.lifebreath.com

PERFORMANCE

Net supply airflow in cfm (L/s) against external static pressure

E.S.P

cfm

L/s

@ 0.1” (25 Pa)

214

(101)

@ 0.2” (50 Pa)

206

(97)

@ 0.3” (75 Pa)

193

(91)

@ 0.4” (100 Pa)

184

(87)

@ 0.5” (125 Pa)

170

(80)

Sensible Effectiveness
@127cfm (60 L/s)

(CSA C439M)

67%

Sensible Efficiency 32°F (0°C)

60%

Total Efficiency

55%

VAC @ 60HZ

120

WATTS / Low speed

70