NEVER

aim active unit at intense light sources (i.e. lights,

headlamps, campfires, the moon, etc.)

NEVER

reverse the polarity of a battery

NEVER

connect the unit to external power sources

ALWAYS

remove batteries when not in use for an

extended period of time

ALWAYS

keep the objective lenses covered

when not in use.

ALWAYS

store in a warm dry place when not in use


THANK YOU FOR PURCHASING THE NIGHT VISION
RIFLE SCOPE DN-140M.
PLEASE REQUEST TO CHECK THE DEVICE FOR
PROPER OPERATION BEFORE PURCHASE.
PLEASE READ ALL THE INSTRUCTIONS
CAREFULLY BEFORE USING.

2. OVERVIEW

The night vision riflescope DN-140M is an observational

optico-electronic monocular device intended for precise shooting,
and examining a distant objects orientation at night. The unit
utilizes an image intensifier, which amplifies available
moonlight,

4

8. TROUBLESHOOTING

The scope does not work.

- Check that the batteries are installed properly.
- Check the charge of the batteries. Replace if they are weak. Do
not use old batteries with new ones.

The image does not appear in focus.

Bring the inspected object to the center of the image. Turning the

objective lens ring (7), and/or the eyepiece (2) adjust to achieve
the clearest image on the screen. Repeat the steps of focusing if
necessary

If the view still does not seem in focus, clean the lenses; they

could be foggy or dusty.

Unit flashes

It is normal for the unit to flash within the first 2 minutes of

activation. If the flashing continues afterwards the following is a
possible cause: bright environment (even with the cap closed!)

Condensation accumulates on the parts.

It is O.K. to use the scope in cold. However, when the unit is

brought from the cold into a warm environment, it has to

warm up for up to 5 hours (not minutes!). Only then should it be

turned ON again.

Visibility decreases and / or disappears.

Bright light sources (moon, projectors or headlights) may cause
visibility to degrade or even completely disappear. Move the
scope away from the light source immediately.