Slot 1 slot 2, Install director network modules, Install sfp and xfp monitor port modules – Net Optics Smart Filtering none User Manual

Page 17: Rack mount the director device

Advertising
background image

13

*** Confidential - DO NOT Distribute ***

Director

Install Director Network Modules

If the Director Network Modules (DNMs) are not already installed when you receive the unit, install them by sliding

them into the DNM slots in the front panel. (If there is a plate covering the DNM slot, remove it by unscrewing two

thumb-screws, and then install the DNM module.) The DNM circuit boards ride in the rails provided in the slots. Push in

the DNM firmly until you feel the connectors mate and the bezel is flush with the front panel, but do not force them. If you

encounter resistance, withdraw the module and try again, making sure to align the circuit board in the rails and slide the

module straight in. When the DNM is fully seated, fasten it to the front panel with the two captured thumbscrews.

If you are only using a single DNM, it should be installed in the left slot (Slot 1).

www.netoptics.com

1

2

B

A

A

B

Slot 1

Slot 2

Installing Director Network Modules

Figure 8:

Install SFP and XFP Monitor port Modules

SFP and XFP modules are shipped separately. Install them as desired in the SFP and XFP slots in the front on the chassis,

and the two XFP slots in the rear. For each module, remove the temporary plug from the SFP or XFP slot and insert the

module until it clicks into place. The photograph on the cover of this Guide shows properly installed SFP and XFP modules.

Rack Mount the Director device

Director is designed for rack mounting in a 19-inch rack panel. The panel occupies one rack unit. To rack mount the

Director device, simply slide it into the desired rack location and secure it using the four supplied screws.