Model 200ervd, Performance, Engineering data – Lifebreath MAXTOP User Manual

Page 15: Dimensions 200ervd

Advertising
background image

15

OPTIONS
99-104

Digital Electronic Timer - 20/40/60 min. (3 wire)

99-109

Air Sentry™ Air Quality Monitor designed to accept
remotely mounted Control Pad.

99-186

Weatherhoods, Two - 6” (150mm) c/w 1/4” (6mm) mesh
screen

WARRANTY
Units carry a 5 year warranty on the energy recovery core and
replacement parts.

ERVs are not recommended for regions where the design tempera-
ture is below 25°F (-4°C)

TI-200ERVD

0107

All units conform to
CSA and UL standards.

Model 200ERVD

ENGINEERING DATA

LATENT RECOVERY/MOISTURE TRANSFER CORE
The cross-flow energy recovery core transfers heat and water vapour
between the two airstreams. It is easily removed for cleaning or service.
MOTORS AND BLOWERS
Each air stream has one centrifugal blower driven by a common PSC motor.
5 speed fan operation. High speed - 120 VAC.
FILTERS
Washable air filters in exhaust and supply air streams.
MOUNTING THE ERV
Four threaded inserts at corners of case designed to accept four PVC rein-
forced polyester straps that are supplied with the unit.
DEFROST
Damper defrost system.
DEHUMIDISTAT
Adjustable internal dehumidistat.
CASE
Twenty gauge prepainted galvanized steel (G60) for superior corrosion resis-
tance. Insulated to prevent exterior condensation.
DRAIN CONNECTIONS
Two - 1/2” (12mm) O.D.
CONTROLS
ControlAir 15 - Standby/ON mode, 20 ON/ 40 OFF mode (each mode has 5
speeds). Control pad can be removed from HRV and remotely mounted.

Weight 63 lbs. (28.7 kg)

Shipping Weight 65 lbs. (29.6 kg)

STALE AIR

TO OUTSIDE

STALE AIR

FROM HOUSE

FRESH AIR

TO INSIDE

14

3

/

4

"

(375)

19"

(483)

*

All Duct Connections 6"(150mm)

FILTERS

*NOTE: Front clearance
of 25 inches (635 mm)
is recommended
for ser vicing unit.

MOTOR

31"

(787mm)

FRESH AIR

FROM OUTSIDE

DAMPER

DEFROST

PORT

CONDENSATE DRAINS

ENTHALPIC

CORE

BALANCING DAMPER

DIMENSIONS 200ERVD

inches (mm)

Date: ___________________________________________

Tag: _____________________Qty:___________________

Project: _________________________________________

Engineer: _______________________________________

Contractor: ______________________________________

Supplier: ________________________________________

Quote#: _________________________________________

Submitted by: ____________________________________

*Sensible Efficiency – thermal **Latent Efficiency – moisture
Note: Effectiveness - based on temp. differential between the 2 airstreams
Efficiency – takes into account all power inputs

Performance

Net supply air flow in cfm (L/s) against external static pressure

E.S.P

(external static pressure)

[cfm (L/s)]

@ 0.1" (25 Pa)

214 (101)

@ 0.2" (50 Pa)

206 (97)

@ 0.3" (75 Pa)

193 (91)

@ 0.4" (100 Pa)

184 (87)

@ 0.5" (125 Pa)

170 (80)

@ 0.6" (150 Pa)

155 (73)

@ 0.7" (175 Pa)

137 (65)

Sensible Effectiveness
@ 127 cfm (60 L/s)

32°F (0°C)

67%

*Sensible Efficiency
@ 127 cfm (60 L/s)

32°F (0°C)

60%

Total Efficiency

55%

VAC @ 60HZ

120

WATTS / Low speed.

70

WATTS / High speed

182

Amp rating

1.4

1

2

3

20

40

60

80

100

120

140

160

180

200

220

240

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

Static Pressure (in w.g.)

A

ir

Flow (

c

fm

)

3 - High Speed
2 - Medium Low Speed
1 - Low speed