The basic zone configuration for the F-64 Panel is 8
zones. Connect as shown above to terminals 13-24.
Normally Closed (N.C.) devices may be wired in series
or Normally Open (N.O.) devices may be wired in
parallel. Use the 2.2K Ohm end-of-line (E.O.L.) resistor
in each zone, if selected in programming (refer to the F-
64 Programming Instructions WI1502). Zones 1-8 can
be selected for a “Fast Loop Response (50 ms)” or a
“Normal Loop Response (750 ms)”. Other zone options

include Zone Type (Entry/Exit, Interior, 24 Hour Protection, Trouble and Fire), Instant, Chime, Area Selection and
PGM Output selection. Additional expansion zone modules or wireless sensor transmitters/receivers can be used
to obtain zones numbered 9 through 32.

EZ ZONE DOUBLING

TM

CONFIGURATION

The control panel zone configuration may be expanded
from 8 to 16 zones without the use of EZM Modules. To
do so simply select “EZ Zone Doubling” in programming
(refer to the F-64 Panel Programming Instructions WI1502)
and connect zones as shown above. NOTE: If both zones

in a zone-pair configuration (ex: zones 1 & 9 in the above
diagrams) are to be used, then normally closed devices
must be wired to both zones. The 3.9K EOL resistor must
be placed at the end of the loop of the higher zone and the
2.2K EOL resistor must be placed at the end of the loop of
the lower zone.

If Normally open zones for fire or panic devices are required, then the lower zone (2.2K EOL resistor) must be used
and the higher zone (3.9K EOL resistor) must not be programmed for any area. Additional expansion zone
modules or wireless sensor transmitters/receivers can be used to obtain zones numbered 9 through 32

WARNING: Assigning a fire zone or keyswitch zones to a zone doubled will disable the respective complimentary

zone. For example, if zone 8 is assigned as a fire zone, it will disable zone 16. If zone 3 is assigned as a fire zone, it
will disable zone 11.

( – )