Glossar y – Napco Security Technologies WI1501A User Manual

Page 29

Advertising
background image

L

NAPCO Security Systems

Freedom F-64 Installation Instructions

WI1501A 9/06



Page 29

a Priority Zone must be corrected before the panel can be armed. Any zone may be selected as a Priority Zone. A zone in trouble that
is neither a Priority Zone nor an Auto-Bypass Zone will cause an alarm on arming.

Priority Zone with Bypass
A Priority Zone that will permit arming if the priority condition is bypassed. If the system is so programmed, the zone will auto-bypass
and (optional) the condition will be reported to a central station.
As above, if an attempt is made to arm, the sounder will come on and a warning message will be displayed indicating that the system
cannot be armed. The display will read "

ZONE FAULTED

" and will list the faulted zone. To arm the panel, press BYPASS to enter the

Bypass Menu. The first Menu item is "DISPLAY ZN DIRECTORY Y/N". Press YES to list all zones in your system. Scroll forward or
backward through the zone list using the YES and NO buttons, and as you scroll through each zone, the Bypass or Trouble icons
will appear (or not appear) depending on the status of each zone. When the zone that you wish to bypass appears on the Touchpad
LCD window, press BYPASS. The Bypass icon will appear. Press RESET to continue. Note: Any zone not selected as a Priority
Zone may be programmed as a Priority Zone with Bypass.

Pulse Burglary Output See Alarm Outputs

Receiver Format
The communicator can be programmed to transmit to any standard central-station receiver format. A receiver format must be entered for
each telephone number used, but a different format may be assigned to each. Refer to Backup Report on Telco 2 and Report Telco 3 to
determine whether or not Telephones 2 and/or 3 will be programmed. Call the central station for each telephone number used to confirm
the type of receiver in use. Select the receiver format entry for each telephone number from the following table.














*These formats do not use programmable codes, but Event ID Codes to identify the type of zone and alarm as follows:
1 – Fire
2 – Panic
3 – Burglary
4 – Holdup
7 – Gas Alarm
8 – Heat Alarm
A – Auxiliary Alarm (LCD window displays "0")
B – 24-Hour Auxiliary Alarm


Relay Control (Optional External Relays)
In addition to the three relay outputs (Alarm, PGM1 and PGM2) provided on the motherboard, up to 16 external relays can be controlled
through the use of the RM3008 (self-contained) or the RB3008 (to be mounted inside housing). The GEM-OUT8 is similar to the
RM3008 but has open collector active low outputs in place of relays. The GEM-OUT8 is designed for external remote mounting, and
one module may be used with the F-64 Control Panel. Use the RM3008, RB3008 or the GEM-OUT8 for 16 independent programmable
active low outputs for controlling 32 relay events, which can be assigned to any of the 16 available external outputs. Multiple relay
events can drive the same external relay.

Relay Follows Zone
External Relays can be programmed to follow a zone. If values are entered in Time locations, the relay will time-out after the
programmed time.

Remote Panic
See Panic Zone

Report Digital Dialer Exit Error/Recent Closing

A Recent Closing transmission is sent if an alarm occurs within two (2) minutes after the expiration of the Exit Time. If the user number

ENTRY

RECEIVER FORMAT


blank (•)

Ademco, Silent Knight Slow

2

Radionics Fast

3

Silent Knight Fast

4

Radionics, DCI, Franklin Slow

5

Universal Hi-Speed

B

SIA*

C

Ademco Point ID*

E

Pager

DATA

FREQ.

(Hz)

DUTY CYCLE

(ON/OFF)

INTERDIGIT

TIME

1900

60/40mS

600mS

1850

13/12

400

1900

40/30

560

1800

60/40

600

1850

30/20

350

Modem formats

Glossar

y

Advertising