Wiring connections – Napco Security Technologies GEM-P1664 User Manual

Page 12

Advertising
background image

X

GEM-P1664 Installation Instructions

L

NAPCO Security Systems

WI1424A 1/06



Page 12

WIRING CONNECTIONS

BATTERY

The RED (+) and BLACK (-) flying leads must be connected
to a 12VDC 4-7 AH Rechargeable Battery, to serve as
backup power in the event of AC Power Failure. NOTE: To

calculate the available standby time refer to the Standby-
Battery Calculation Worksheet at the back of this manual.

TRANSFORMER

(The following applies to installations in the United States of America): Connect
a 16.5 VAC Transformer to Terminals 1 and 2, using a wire of #18 AWG. or
larger at a distance of 15 ft. or less from the control panel. NOTE: Do not

connect to a switched outlet.

Connect the alarm sounding devices (self-contained sirens,
speakers or a mechanical bell) to Terminals 3 and 4. Any self-
contained siren requiring a 12 VDC input can be connected.
When connecting a mechanical bell, it must be supervised
using a 2.2k Ohm resistor. To connect 8 Ohm Speakers use a
Siren Driver with the proper polarity observed. NOTE: Refer to

the GEM-P1664 Wiring Diagram for alarm current
specification. Note: In NFPA Household Fire Installations.

only a single siren or bell can be used on this bell circuit.

SIREN/BELL POWER

AUXILIARY POWER

Connect the auxiliary devices (motion detectors, glass breaks, etc.) to Terminals 5
and 6. Auxiliary Power provides 11.7-12.5 VDC nominal output which is used for
powering auxiliary devices. NOTE: To calculate the available standby time refer to

the Standby-Battery Calculation Worksheet at the back of this manual.

PGM OUTPUTS (PGM1 & PGM2)

PGM1 and PGM2 are negative switched
programmable outputs that can be activated
depending on the programming options
selected (see GEM-P1664 Programming
Instructions). Connect the device controlled by
the programmable output between terminal 5
(+) and the PGM output (-), either terminal 7 or
8. As an example, the connection to the
RB1000 Relay Module is shown.

7

Wiring Connections: Batter

y,

Tra

n

sformer, Siren

Pow

er,

A

u

x. Po

w

er &

PG

M Ou

tpu

ts

Advertising