GEM-P1664 Installation Instructions

L

NAPCO Security Systems

WI1424A 1/06



Page 24

DISPLAY ZN BYPASSED

Press YES button to display zones that have been deactivated. Press NEXT button to scroll through the zones.

DISPLAY ZN DIRECTORY

Press YES button to display a list of all programmed zone descriptions in the keypad area. Press NEXT button to

scroll through the zones. To return to the system, press the

C

button at any time.

ACTIVATE BELL TEST
Press the NEXT/YES button to activate the burg relay output (while disarmed) for about 2 seconds. If the device does
not sound, it may be defective.

DISPLAY FIRE ALARM

To display Fire Zone(s) in alarm, access DISPLAY FIRE ALARM and scroll through the zones using the NEXT but-

ton. Correct the problem, then press the

C

button to restore the "SYSTEM READY" condition.

DISPLAY FIRE TRBL

To display Fire Zone(s) in trouble, access DISPLAY FIRE TRBL and scroll through the zones using the NEXT but-

ton. Correct the problem, then press the

C

button to restore the "SYSTEM READY" condition.

ACTIVATE CHIME
Press the NEXT/YES button to sound a tone at the keypad when a Chime Zone is violated. The duration of the tone is
programmable. To turn off the Chime Mode, press the NEXT/YES button at the DEACTIVATE CHIME function. Note:

Chime is disabled for protected zones while armed. Never Armed zones (such as a driveway sensor) will continue to
chime when the system is armed.

RESET SYSTEM TRBL



System troubles normally latch and display and sound at the keypad. Pressing the

C

button will si-

lence the sounder; "SYSTEM READY" will be displayed. Correcting the trouble will clear most system trouble
indications, however the following system troubles require a reset system trouble be performed (enter code;
access RESET SYS TRBL then press the

U

or

D

button).



Sensor Watch

Note: (1) If a system trouble is not corrected, it will redisplay after 5 minutes. (2) If one or more of the foregoing

system troubles appear during the first 5 minutes after power-up, they will be cleared automatically.

DISPLAY ALARM LOG (Not available with GEM-RP2ASe2/GEM-K2AS or GEM-RP3DGTL/GEM-K3DGTL Keypads)

Displays most recent alarm events. Line 1 displays event and date. Line 2 displays time, area and zone. To

check previous alarm events, scroll back using the PRIOR button.

DISPLAY TOTAL LOG (Not available with GEM-RP2ASe2/GEM-K2AS or GEM-RP3DGTL/GEM-K3DGTL Keypads)

Displays most recent events of all types. Line 1 displays event and date. Line 2 displays time and, if applicable,

area and zone or user. To check previous events, scroll back using the PRIOR button.

DISPLAY FIRE LOG (Not available with GEM-RP2ASe2/GEM-K2AS or GEM-RP3DGTL/GEM-K3DGTL Keypads)

Displays most recent fire events. Line 1 displays event and date. Line 2 displays time, area and zone. To check

previous fire events, scroll back using the PRIOR button.

DISPLAY OP/CL LOG (Not available with GEM-RP2ASe2/GEM-K2AS or GEM-RP3DGTL/GEM-K3DGTL Keypads)

Displays most recent openings and closings. Line 1 displays event and date. Line 2 displays time, area and user.

To check previous events, scroll back using the PRIOR button.

DISPLAY SYSTEM LOG (Not available with GEM-RP2ASe2/GEM-K2AS or GEM-RP3DGTL/GEM-K3DGTL Key-
pads)

Displays most recent system events. Line 1 displays event and date. Line 2 displays time and other pertinent in-

formation, where necessary, depending upon event. To check previous system events, scroll back using the PRIOR
button.