Troubleshooting, Problems with recording – Roland Portable Recorded R-26 User Manual

Page 98

Advertising
background image

98

Troubleshooting

If you experience problems, refer to the information provided here.
If this information does not help you solve the problem, please contact a customer service

location listed at the end of this manual.

Problems with Recording

Problem

Cause

Page

Sound recorded

from the mic is heard

only from the L (left)

channel

If you’re using a monaural mic, only the L (left) channel will be recorded.
If you use an external mic, check whether the mic is stereo or monaural.
In order to record onto both channels using a monaural mic, use the “MIC

TYPE” screen to set the external mic type to “MONO.”

p. 40

Can’t start recording

Recording will not be possible if the SD card has less than 16 kilobytes of

free space. Nor can you enter recording-standby mode.

p. 95

Recording begins at

a different point than

when you started

If PRE-REC is on, the sound will be recorded starting two seconds before

you press the [ ] button.

p. 34

Recording will start automatically when the unit detects input that is above

a certain level, if the automatic recording start feature is on.

p. 35

Recorded sound is

distorted

The sound will be distorted if the input level or the input sens is too high.

Adjust the recording level appropriately.

p. 43

Can’t play back the

recorded project

If you inadvertently disconnect the adaptor or remove the SD card during

recording, the project will be damaged and cannot be played. In some

cases you may be able to use the project Repair function to recover it.

p. 77

Can’t record

Recording is not possible if the SD card is not inserted correctly. Turn off the

power, and re-insert the SD card.

p. 26

If the SD card has not been formatted, it will not be recognized, and the

display will indicate “SD Unformatted.” Please format the SD card.

p. 27

The SD card will not work properly unless it was formatted on the R-26.

If the card was formatted using a computer, it might have the wrong

format. In this case, it might stop immediately after recording is started, or

recording might not occur correctly.

p. 27

Recording is not possible if the SD card is write-protected (LOCK). Turn off

write protection.

p. 28

Recording will not occur correctly if the recording level is too low. Set the

recording level appropriately.

p. 43

Project was divided

unexpectedly

The R-26 will automatically divide the project if the file currently being

recorded exceeds a specified size, or if the recording level falls below a

specified level. Set the Split Type setting to specify the file size or recording

level at which the file is to be automatically divided.

p. 50

The volume level of

the instrument con-

nected to ANALOG IN,

PLUG IN is too low .

Could you be using a connection cable that contains a resistor?
Use a connection cable that does not contain a resistor.

p. 15

No sound received

from condenser mic

In order for sound to be received from a condenser mic, phantom power

must be turned on. Turn on phantom power.

p. 39

Advertising