Attention, Wiring alternatives for bf actuators, Achtung – RedMax REVOLUTION -5.10-BF User Manual

Page 6: Exmax-...-bf, redmax-...-bf, On-off and 3-pos, On-off 1-wire, On-off 1-wire - spring return + eex-i circuit, O-off/3-pos - spring return + eex-i circuit, On-off 1-wire - spring return + eex-d limiter, Values of the eex-i circuit

Advertising
background image

ExMax-...-F, ExMax-...-SF, RedMax-...-F, RedMax-...-SF

PA

PA

ExMax-...-BF, RedMax-...-BF

PA

PA

PA

U

0

= 10,6 V

I

0

= 11 mA

P

0

= 30 mW

C

i

= 0

L

i

= 0

IIC

IIB

IIA

C

0

830 nF 3,7µF 4,5 µF

L

0

2 mH

5 mH 10 mH

Schischek GmbH Germany D-90579 Langenzenn, Mühlsteig 45, Gewerbegebiet V, Tel. ++49 (0)9101-90810, Fax ++49 (0)9101-908177, Email [email protected]

ExMax-.. and RedMax-.. extra information EL - size S

E X P L O S I O N P R O O F

Wiring alternatives for on-off and 3-pos actuators with spring return

On-off and 3-pos

1

2

3

4

~

-

~

+

PE

heater

5

24 to 230 VAC/DC

a

b

If 3 sec. mode is selected, the self adju-

stment of angel of rotation must be started

and operation mode of max. 10% ED

must be guaranteed.

Never operate actuator in the 3 sec mode

without an outside load of min. 3 Nm.

Engaging 1 wire On/Off controlls in the

3 sec. modus with spring return, the ac­

tuator can only be operated with 1 On/Off

function per minute otherwise electronics

will be liable to overheating.

Attention!

!

!

On-off 1-wire

1

2

3

4

~

-

~

+

PE

heater

5

24 to 230 VAC/DC

a

Wiring alternatives for BF actuators

On-off 1-wire - spring return + EEx-i circuit

1

2

°C

push button

6 7

< 5 °

8

9 10

> 85 °

11

1

2

3

~

-

~

+

PE

heater

5

24...230 VAC/DC

FireSafe

4

O-off/3-pos - spring return + EEx-i circuit

1

2

°C

6 7

< 5 °

8

9 10

> 85 °

11

1

2

3

~

-

~

+

PE

heater

5

24...230 VAC/DC

FireSafe

4

a

b

On-off 1-wire - spring return + EEx-d limiter

1

2

°C

Push button

The intrinsic safe circuit must

be closed otherwise the

actuator is unable to work!

6 7

< 5 °

8

9 10

> 85 °

11

1

2

3

~-

~+

PE

heater

5

24...230 VAC/DC

4

Limiter

Values of the EEx-i circuit

Achtung!

!

!

EXC-DS1/VA

If 3 sec. mode is selected, the self adju-

stment of angel of rotation must be started

and operation mode of max. 10% ED

must be guaranteed.

Never operate actuator in the 3 sec mode

without an outside load of min. 3 Nm.

Engaging 1 wire On/Off controlls in the

3 sec. modus with spring return, the ac­

tuator can only be operated with 1 On/Off

function per minute otherwise electronics

will be liable to overheating.

! Attention !

If you use this type of

wiring the heater does

not work in case of

open contact.

! Attention !

If you use this type of

wiring the heater does

not work in case of

open contact.

! Attention !

If you use this type of

wiring the heater does

not work in case of

open contact.

Standard wiring = spring return in ~10 sec.

Additional wiring terminal 5 = spring return in ~ 3 sec.

Standard wiring = spring return in ~10 sec.

Additional wiring terminal 5 = spring return in ~ 3 sec.

Standard wiring = spring return in ~10 sec.

Additional wiring terminal 5 = spring return in ~ 3 sec.

Standard wiring = spring return in ~10 sec.

Additional wiring terminal 5 = spring return in ~ 3 sec.

Standard wiring = spring return in ~10 sec.

Additional wiring terminal 5 = spring return in ~ 3 sec.

Integrated aux. switches

max 24V/3A, 230V/0,5A

switching at 5° and 85°.

Supply at aux. switches must

be the same like supply of the

actuator on same fuse in case

that power is switched.

Integrated aux. switches

max 24V/3A, 230V/0,5A

switching at 5° and 85°.

Supply at aux. switches must

be the same like supply of the

actuator on same fuse in case

that power is switched.

Integrated aux. switches

max 24V/3A, 230V/0,5A

switching at 5° and 85°.

Supply at aux. switches must

be the same like supply of the

actuator on same fuse in case

that power is switched.

EEx-i circuit for

passive + potential free

push button on site

and safety temperature sensor

(Type FireSafe accessories)

EEx-i circuit for

passive + potential free

push button on site

and safety temperature sensor

(Type FireSafe accessories)

push button

B

A

B

A

B

A

SB 2.0

SB 2.1

SB 7.0

SB 7.1

SB 7.2

www.schischek.com