SECTION 2: I

NTRODUCTION

7

2.8 Components Identification

FIGURE 1: Components Identification

Burner - Contains the electrical components (i.e.
blower motor, power transformer, etc.) and gas distri-
bution components (i.e. gas valve, etc.) that make
the heater work. There are no owner serviceable
items contained in this box.

Front Fixed Hanger - Provides rigid support and
mounting surface for the reflector. Holes are provided
in the upper corners of the bulkhead to accommo-
date suspension hardware required for installation of
the heater.

Reflector - The reflector is made from formed alumi-
num and reflects the radiant energy downward to the
space to be heated.

Heat Exchanger - A U-shaped tube through which
the heated products of combustion pass.

Rear Movable Hanger - Provides support for the tube
and reflector at the end that is furthest from the burner.
The support may be moved (within limits) to accom-
modate hanging of the unit.

Service Door - To be removed only by a contractor
qualified in the installation and service of gas-fired
heating equipment or your gas supplier. Removal of

this service door provides access to the electrical
and gas distribution components.

Gas Line - Must only be installed and serviced by a
licensed contractor or gas fitter.

Wall Termination Plate - Placed on the outside wall
over the venting.

Venting - Installer must properly exhaust the heater
outside. The 5” outer duct carries fresh air to the
burner. The 3” inner duct carries the products of com-
bustion to the outside.

Thermostat - 24 Volt Thermostat mounted with
Safety Tag.

Protective Grille - Included with select models. See
Page 20, Section 4.14
for details.

Vent Collar - Accommodates a 5" (125 mm) diame-
ter combustion air inlet duct that delivers fresh air to
the burner. The fresh air enters the burner through
the twelve equally spaced holes shown above. The
3" (80 mm) diameter hole in the center of the flue col-
lar accommodates the venting duct that carries the
products of combustion to be vented outdoors.

Reflector

Heat Exchanger

Burner

Front Fixed Hanger

Rear Movable

Hanger

Service Door

Venting

Wall Termination Plate

Gas Line

Protective Grill

Manual Gas

Shut-off Valve

Thermostat

Connection

Power

Cord

Nipple 3/8”

(10 mm) NPT

Vent Collar

Fire Hazard

Some objects will catch fire or

explode when placed close to

heater.

Keep all flammable objects,

liquids and vapors the required

safe distances away from heater.

Keep children, clothing and

furniture away from the heater.

Failure to follow these

instructions will result in death,

injury or property damage.

WARNING

Printed in U.S.A./Imprimé aux Etats-Unis

This thermostat controls your overhead tube heater. Keep burner, control compartment and reflector clean. Read

your CGTH-Series Use and Care Manual (P/N 180101NA or GH80101NA) and follow all Safety Requirements which

include checking your heater monthly. Installation, Service and Annual Inspection must be done by a contractor

qualified in the installation and service of gas-fired heating equipment. Please call (716) 852-4400 (USA) or (905)

945-5403 (Canada) if you need a manual or have questions.
Ce thermostat commande votre radiateur. Gardez le module de contrôle et le reflécteur propres. Lisez le manuel

d’utilisation et d’entretien CGTH-Series (P/N 180101NA ou GH80101NA) et respectez tous les conseils de sécurité,

notamment le contrôle mensuel du radiateur. L’installation, l'entretien et l’inspection annuelle doivent être effectués

par un agent agréé. Veuillez nous contactez au 716-852-4400 (USA) ou au 905-945-5403 (Canada) pour toutes

questions ou demandes de manuel.

MOUNT

THERMOSTAT

HERE

MONTER LE

THERMOSTAT ICI

ATTENTION

Risque d'incendie

Certains objets placés près du

radiateur peuvent s'enflammer ou

exploser.

Tenir tous les objets, iquides et

vapeurs inflammables à la

distance de sécurité requise du

radiateur.

Surveiffer les enfants. Gardes les

vêtements, les meubles loin de

l'appareil.

Le non-respect de ces consignes

peut causer dommage au matériel.

Required Safe Distances from Combustibles

Distances de Dégagement par Rapport aux Combustibles

Horizontal Mount

Montage Horizontal

45° Mount

Montage à 45°

24" Min. (61 cm)

A

A

D

D

E

E

A

A

FF

Approx. 45 °

F

B

A

C

24" Min. (61 cm)

B

Rating Tag

Éttiquette de

Classement

by

CGTH-Series

®

NOTES: 1. Toutes les dimensions sont mesurées à partir du réflecteur.

2. Les chiffres noirs sont en pouces.

Les chiffres oranges

sont en centimètres.

3. Vous devrez connaître le numéro de votre modèle. Il se

trouve sur l’étiquette de classement. (Voir le dessin du

montage horizontal pour l’emplacement de l’étiquette de

classement).

Model

A B

C

D

EF

CGTH-30

4 16 36 28 34 6

CGTH-40

4 18 48 30 34 6

CGTH-50

4 20 48 32 36 6

Modèle

A B

C

D

EF

CGTH-30 11 41 92 72 87 16
CGTH-40 11 46 122 77 87 16
CGTH-50 11 51 122 82 92 16

©

www.rg-inc.com

P/N 91037903 Rev F

NOTES: 1. All dimensions are from the reflector.

2. Black numerals are in inches.

Orange numerals are in

centimeters.

3. Know your model number. Model number is found on the

rating tag. (See horizontal mount drawing for location of

rating tag).

Advertising