Figure 2-1, Figure 2-1. mbe pcb layout warning – RAD Data comm MBE10-1D User Manual

Page 30

Advertising
background image

Chapter 2 Installation

MBE Family Installation and Operation Manual

2-4

Installation and Setup

9. To enable direct connection between MBE and a UTP interface in any

workstation, set the STATION/HUB Switch to STATION (see

Figure 2-4

). This is

available only with the UTP option.

10. Replace the MBE cover.
11. Close by tightening the cover screw.
12. Proceed with the line, LAN and power connections as described below.

In certain locations where permanent excessive high voltages are present on
the lines, setting JP7 to NC may render the unit unsafe for connection to
unprotected telecommunication networks.

Power Supply

EPROM

MAIN

REMOTE

RESET

LOCATION

SW1

SW2

512K

128K

JP7

WATCH DOG

NC

OFF

ON

ON

CHASSIS

Link Interface

Module

LAN Interface

Module

AUI

BNC
UTP

Fuse
240 VAC/2A
Slow-Blow

Figure 2-1. MBE PCB Layout

Warning

Order from: Cutter Networks

Ph:727-398-5252/Fax:727-397-9610

www.bestdatasource.com

Advertising