Guardshield safe 4, Operation manual – Rockwell Tools GUARDSHIELD SAFE 4 User Manual

Page 10

Advertising
background image

GuardShield Safe 4

Operation Manual

5.1.5. Distance to reflective surfaces

Reflective surfaces may cause reflections within
the transmitter and receiver aperture angle, i.e.
an interruption of the protective field would not be
recognized (Figure 7).

Figure 7: Distance to reflective surfaces

Should reflective surfaces arise, i.e. aluminium
container passing near the light curtain or if the
danger point itself is reflective, i.e. a steel blade, the
safety distance S

2

must be increased, such that no

reflective surface lies within the distance S

2

.

The increase of the safety distance is dependant of
the actual operation range R according to IEC 61496
and may be calculated as follows:

Safe4

S2 = 72 mm

for R < 3 m

S2 = R x 0.0219

for R ≥ 3 m

5.1.6. Multiple light curtain arrangement

When using several optoelectronic safety devices

in the same application, the systems should be
installed in such a way that they cannot interfere
with each other. Care must be taken that each
receiver only receives light from its own transmitter
(Figure 8).

Figure 8: Multiple light curtain arrangement

10

Receiver

Transmitter

Transmitter

Receiver

Transmitter

Receiver

Transmitter

Receiver

The safety light curtain has been thoroughly

tested against light interferences according to the
stringent requirements of IEC 61496. Nevertheless
any direct interference into the receiver with other
infrared sources like through beam photoelectric
sensors, laser scanner, transmitters etc. should be
avoided.


5.2. Mechanical installation

Be aware that a rigid, flat base, isolated against

shock and vibration should be selected to mount
the GuardShield Safe 4. This in combination with
the standard mounting brackets set will keep the
initial alignment during operation even in harsh
industrial environments.

5.2.1. Mounting brackets

The backside of the light curtain profile has

continuous grooves to attach the mounting
brackets at any position along the light curtain
housing (Figure 18).

Each system is delivered with four mounting

brackets.

Optional available mounting brackets (Figure 9):

Vertical mounting brackets for mounting the
light curtain in the vertical axis of the light
curtain. (± 4

o

adjustable)

POC and SICK FGS mounting profiles (not
adjustable

The mounting brackets contain all necessary
mounting parts and a separate instruction sheet
to help ensure that the parts are assembled
properly.

5.2.2. Intelligent Laser Alignment System ILAS

WARNING: Class 2 Laser
Do not expose your eyes to the
laser beam to prevent exposure to
dangerous radiation!
Turn ILAS off if not used!

To switch on ILAS:

Touch the hand symbol

Operation: Laser beam is blinking

To switch off ILAS:

Touch the hand symbol again

Automatically after 5 minutes

dangerous point

reflective surface

E

R

optical axis

S

2

R

Advertising
This manual is related to the following products: